Availability: | |
---|---|
Quantity: | |
Shanghai, China
8000
T/T
Anticorrosive Steel Lined Plastic PTFE ,LLDPE Pipe Use for Sulfuric Acid Hydrochloric Acid HCL, NaOH, NaCLO,
Steel lined piping with tetrafluoride
Molded piping with tetrafluoride
Anticorrosive pipeline resistant to high temperature and negative pressure
Chemical pipeline
Metal cans Steel-Lined Plastic Square Tank, Electrolytic Tank, Pickling Tank Acid Containment Vessels Custom Made Rotationally Molded Linear Resins LLDPE
Custermizing Checmial Acid Storage Tank 60 m3 Steel Lined LLDPE Tank Used to Contain: HCl (max 35%) , Naoh (max 50%) , Naclo (max 10%) , PAC (max 17%) ,H2so4
Used to contain: HCl (max 35%), NaOH (max 50%), NaCLO (max 10%), PAC (max 17%), H2SO4 etc
Media (density) : (1155 Kg/m3), Hydrochloric Acid (1150 Kg/m3), Sulfate, Nitrate (1152 Kg/m3), Phosphate (1151 Kg/m3), Hydrofluoric Acid (1132 Kg/m3), Battery Fluid (1135 Kg/m3), Chloride (1135 Kg/m3), Ferric Chloride Solution (1130 Kg/m3), Sodium Hypochlorite (1130 Kg/m3), Sulfurous Acid (1030 Kg/m3)
processing/storing; aluminum sulfate, ammonium sulfate, calcium chloride, ethylene glycol, ferric chloride, ferric sulfate, ferrous sulfate, hydrochloric acid, hydrofluoric acid, hydrofluosilicic acid, hydrogen peroxide, magnesium chloride, phosphoric acid, polymers, potassium hydroxide, or just plain water and we'll design the vessel(s) you require.
Horizontal / Vertical Storage HCL Acid Tanks Steel Lined LDPE 120000 Liters
For Storage Bleach, Hydrochloric Acid, Ferric Chloride, Oilfield Chemicals, Corrosive Wastes And Other Hazardous Cargoes.
Steel ( 6 mm -8mm ) Lined PE Plastic 7042 (16mm - 25 mm ) storage tank
Specification | General PTFE thickness and negative pressure-resistance | The thickness of PTFE wall required to resist-0.1MPA pressure when the temperature is less than 120degree, | |
DN25 | 2mm | -0.08Mpa | 3mm(L≤3000mm) |
DN32 | 2mm | -0.075Mpa | 3mm(L≤3000mm) |
DN40 | 2.5mm | -0.075Mpa | 4mm(L≤3000mm) |
DN50 | 2.5mm | -0.06Mpa | 5mm(L≤3000mm) |
DN65 | 2.5mm | -0.05Mpa | 8mm(L≤1000mm) |
DN80 | 3mm | -0.05Mpa | 10mm(L≤1000mm) |
DN100 | 3mm | -0.04Mpa | 13mm(L≤1000mm) |
DN125 | 4mm | -0.03Mpa | 13mm(L≤1000mm) |
DN150 | 4mm | -0.025Mpa | 13mm(L≤1000mm) |
DN200 | 5mm | -0.02Mpa | 15mm(L≤1000mm) |
Specifications:
Nominal Diameter (mm/in. ): DN15-DN600 (NPS 1/2-NPS 24)
Operating temperature: -20-180 degree
Operating pressure: -0.09MPa-1.6MPa (-0.9bar-16bar)
Pipe: Seamless steel.
Flange: ASME B16.5 Class 150 Flange options: HG, GB, JB, JIS, BS, DIN, ANSI, ASTM
Special pieces of specific or non standard size can be manufactured on request.
Carbon steel 45/90degree ptfe lined elbow
Operating temperature: -20-180
Operating pressure: -0.09MPa-1.6MPa
Carbon steel 45/90degree ptfe lined elbow
1. Positive pressure: It shall adopt steel components according to different technical requirements, and the thickness of PTFE wall shall be over 2mm. If the temperature is less than 100 degree, the production length shall be less than 6m; And if the temperature exceeds 100 degree, the length shall be less than 3m.
2. Negative pressure: Design according to different ambient conditions of the users
PTFE lined 90° elbow | Unit mm | ||||||||
Nominal diameter | Specification of balled iron T | Raised face A | Central height C1 | Inside diameter D1 | PTFE thickness | out side diameter of flange D | Diameter of bolt circle K | Thickness of flange C | |
DN(mm) | NPS(inch) | ||||||||
DN15 | 1/2 | 34 | 40 | 80 | 15 | 5 | 90 | 65 | 11 |
DN20 | 3/4 | 38 | 45 | 90 | 18 | 5 | 100 | 75 | 11 |
DN25 | 1 | 42 | 60 | 92 | 22 | 5 | 110 | 85 | 12 |
DN32 | 1 1/4 | 48 | 70 | 100 | 28 | 5 | 130 | 100 | 13 |
DN40 | 1 1/2 | 57 | 80 | 112 | 38 | 5 | 140 | 110 | 14 |
DN50 | 2 | 68 | 95 | 117 | 48 | 5 | 155 | 125 | 14 |
DN65 | 2 1/2 | 89 | 115 | 135 | 63 | 8 | 175 | 145 | 16 |
DN80 | 3 | 108 | 130 | 150 | 78 | 8 | 190 | 160 | 16 |
DN100 | 4 | 114 | 150 | 150 | 87 | 8 | 210 | 180 | 18 |
DN125 | 5 | 140 | 180 | 190 | 110 | 8 | 240 | 210 | 20 |
DN150 | 6 | 168 | 205 | 230 | 135 | 10 | 275 | 240 | 20 |
DN200 | 8 | 219 | 260 | 305 | 180 | 10 | 330 | 295 | 20 |
DN250 | 10 | 273 | 315 | 380 | 230 | 12 | 385 | 350 | 23 |
DN300 | 12 | 325 | 365 | 420 | 280 | 12 | 435 | 400 | 23 |
Key words:
ptfe lined pipe fittings | ptfe lined tee | ptfe lined reducer | ptfe lined elbow | ptfe lined cross |
ptfe lined pipe and fittings | ptfe lined90degree elbow | ptfe lined 45 degrdd elbow | ptfe lined ECC reducer | ptfe lined CON reducer |
ptfe lined equal tee | ptfe lined reduce tee | ptfe lined unequal tee | ptfe lined pipe | ptfe lined fittings |
ptfe lined carbon steel pipe fittings | ptfe lined carbon steel tee | ptfe lined carbon steel reducer | ptfe lined carbon steel elbow | ptfe lined carbon steel cross |
PTFE pipe | PTFE lined pipe(Australia) | Resistant Stainless Steel Pipe | Resistant Steel Pipe | Carbon seamless steel pipe |
Anti Corrosion Pipe Fittings Lined | PTFE lining fittings | PTFE lined piping | straight tee | PTFE lined bends |
The chemical compatibility of LDPE and HDPE on this chart is tested at 20°C: and 50°C: for 7 days and 30 days (if applicable) with constant exposure.
LDPE & HDPE resistance listed by chemical | |
1.4-dioxane | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE at 50°C: shows some effect after 7 days. |
Acetaldehyde | LDPE / HDPE at 20°C: little or no damage after 30 days. HDPE at 50°C: shows some effect after 7 days. LDPE at 50°C: immediate damage may occur. |
Acetic Acid 5 % | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Acetic Acid, glacial 50% | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE at 50 °C: immediate damage may occur. |
Acetone | LDPE / HDPE at 20°C-50°C: damage may occur. Not recommended for continuous use. |
Allyl Alcohol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Aluminum salts | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Amino acids | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ammonia | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ammonium carbonate saturated | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ammonium phosphate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ammonium sulphate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Amyl chloride | HDPE at 20°C: shows some effect after 7 days. HDPE at 50°C & LDPE at 20°C-50°C: immediate damage may occur. Not recommended for continuous use. |
Aniline | LDPE / HDPE at 20°C: little or no damage after 30 days. HDPE at 50°C: shows some effect after 7 days. |
Benzene | LDPE / HDPE at 20°C-50°C: damage may occur. Not recommended for continuous use. |
Benzyl alcohol | LDPE / HDPE at 50°C: immediate damage may occur. HDPE at 20°C: shows some effect after 7 days. |
Boric acid | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Bromine | LDPE / HDPE at 50°C: immediate damage may occur. HDPE at 20°C: shows some effect after 7 days. |
Butyric acid | LDPE / HDPE at 50°C: immediate damage may occur. HDPE at 20°C: shows some effect after 7 days. |
Calcium chloride | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Calcium hydroxide saturated | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Carbon tetrachloride | HDPE at 20°C: shows little or no damage after 30 days. LDPE at 20°C & HDPE at 50°C: show some effect after 7 days. LDPE at 50°C: not recommended. |
Chlorine 10% in water | LDPE / HDPE at 20°C: shows little or no damage after 30 days. LDPE at 50°C: shows damage and is not recommended. |
Chlorobenzene | Immediate damage may occur. Not recommended for continuous use. |
Chloroform | LDPE / HDPE at 20°C: show some effect after 7 days. LDPE / HDPE at 50°C: immediate damage may occur. Not recommended for continuous use. |
Chromic acid 10% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Chromic acid 50% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Citric acid 10% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Cresol | HDPE at 20°C: shows some effect after 7 days. LDPE at 20°C-50°C & HDPE at 50°C: show immediate damage. Not recommended for continuous use. |
Cyclohexane | LDPE / HDPE at 50°C: immediate damage may occur. LDPE / HDPE at 20°C: show some effect after 7 days. |
Diethyl ketone | LDPE / HDPE at 20°C-50°C: damage may occur. Not recommended for continuous use. |
Dimethylsulfoxide | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ethanol 95% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ethyl acetate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ethyl benzene | HDPE at 20°C: shows some effect after 7 days. LDPE at 20°C-50°C & HDPE at 50°C: show immediate damage. Not recommended for continuous use. |
Ethylene glycol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ethylene oxide | HDPE at 20°C: shows little or no damage after 30 days. LDPE at 20°C: and LDPE/ HDPE at 50°C: show some effect after 7 days. |
Ferric chloride | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Fluoride | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Fluorine | HDPE at 20°C: shows little or no damage after 30 days. LDPE at 20°C: shows some effect after 7 days. Not recommended at 50°C. |
Formaldehyde 10% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Formaldehyde 40% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Glycerol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hexane | HDPE at 20°C: shows little or no damage after 30 days continuous use. HDPE at 50 °C: shows some effect after 7 days. LDPE not recommended at any temperature. |
Hydrochloric acid 20% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrochloric acid 35% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrochloric acid 5% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrocyanic acid | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrofluoric acid | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrofluoric acid 4% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrofluoric acid 48% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrogen peroxide 3% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrogen peroxide 30% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Isobutyl alcohol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Isopropyl alcohol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Kerosene | LDPE / HDPE at 20°C: show some effect after 7 days. LDPE / HDPE not recommended at 50°C, as immediate damage may occur. |
Lactic Acid 10 % | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Lactic Acid 90 % | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Lead acetate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Methanol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Methyl ethyl ketone | Immediate damage may occur. Not recommended for continuous use. |
Methyl propyl ketone | HDPE at 20°C: shows some effect after 7 days. LDPE at 20°C-50°C & HDPE at 50°C: Immediate damage may occur. Not recommended for continuous use. |
Methylene chloride | HDPE at 20°C: shows some effect after 7 days. LDPE at 20°C-50°C & HDPE at 50°C: Immediate damage may occur. Not recommended for continuous use. |
Mineral oil | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE at 50°C: may show immediate damage and is not recommended. |
n-amyl acetate | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE at 50°C: shows some effect after 7 days or constant exposure. |
n-butyl alcohol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Nitric acid 50 % | LDPE at 20°C: shows little or damage after 30 days. HDPE at 20°C & LDPE at 50°C: show effect after 7 days. HDPE at 50°C: shows immediate damage and is not recommended. |
Nitric acid 70 % | LDPE / HDPE at 20°C: show some effect after 7 days. LDPE / HDPE at 50°C: show immediate damage. Not recommended. |
n-octane | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Oleic acid | HDPE at 20°C-50°C: little or no damage after 30 days. LDPE at 20°C-50°C: shows immediate damage and is not recommended. |
Oxalic acid | LDPE at 20°C: shows some effect after 7 days. HDPE at 20°C and LDPE / HDPE at 50°C: shows little/ no damage after 30 days. |
Ozone | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE / HDPE at 50°C: show immediate damage. Not recommended. |
Perchloric acid | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE / HDPE at 50°C: show immediate damage. Not recommended. |
Perchloric ethylene | LDPE / HDPE at 20°C-50°C: show immediate damage. Not recommended. |
Phenol | LDPE / HDPE at 20°C-50°C: show immediate damage. Not recommended. |
Phosphoric acid 10% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Phosphoric acid 85% | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE at 50°C: shows immediate damage and is not recommended. |
Phosphorous trichloride | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE at 50°C: has no data available. HDPE at 50°C: shows some effect after 7 days. |
Potassium carbonate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Potassium hydroxide 5 % | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Potassium hydroxide concentrated | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Potassium permanganate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Propylene glycol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Pyridine | Immediate damage may occur. Not recommended for continuous use. |
Salicylic acid, saturated | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Silver acetate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Silver nitrate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sodium carbonate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sodium chloride, saturated | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sodium dichromate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sodium hydroxide 1% | LDPE at 20°C-50°C: shows little or no damage after 30 days. HDPE at 20°C-50°C: shows some effect after 7 days. |
Sodium hydroxide 50% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sodium hypochlorite 15% | HDPE at 20°C-50°C: little or no damage after 30 days. LDPE at 20°C: is suitable but at 50°C: shows some effect after 7 days. |
Sodium nitrate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sodium sulphate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sucrose | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sulfuric acid 20% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sulfuric acid 6% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sulfuric acid 60% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sulfuric acid 98% | LDPE at 20°C-50°C: shows little or no damage after 30 days. HDPE at 20°C: shows effect after 7 days. Not recommended for use at 50°C. |
Tannic acid | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Tetrahydrofuran | LDPE / HDPE at 20°C: show some effect after 7 day of constant exposure. LDPE / HDPE at 50°C: show immediate damage. Not recommended. |
Toluene | LDPE at 20°C: show some effect after 7 day of constant exposure. HDPE at 20°C-50°C & LDPE at 50°C: show immediate damage. Not recommended. |
Trichloracetic acid | LDPE / HDPE at 20°C: show some effect after 7 day of constant exposure. LDPE / HDPE at 50°C: show immediate damage. Not recommended. |
Trichlorethane | Immediate damage may occur. Not recommended for continuous use. |
Turpentine oil | LDPE / HDPE at 20°C: show some effect after 7 days. LDPE / HDPE at 50°C: show immediate damage. Not recommended. |
Urea | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Xylene | HDPE at 20°C: shows some effect after 7 day of constant exposure. LDPE at 20-50°C and HDPE at 50°C: show immediate damage. Not recommended. |
Zinc chloride | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Anticorrosive Steel Lined Plastic PTFE ,LLDPE Pipe Use for Sulfuric Acid Hydrochloric Acid HCL, NaOH, NaCLO,
Steel lined piping with tetrafluoride
Molded piping with tetrafluoride
Anticorrosive pipeline resistant to high temperature and negative pressure
Chemical pipeline
Metal cans Steel-Lined Plastic Square Tank, Electrolytic Tank, Pickling Tank Acid Containment Vessels Custom Made Rotationally Molded Linear Resins LLDPE
Custermizing Checmial Acid Storage Tank 60 m3 Steel Lined LLDPE Tank Used to Contain: HCl (max 35%) , Naoh (max 50%) , Naclo (max 10%) , PAC (max 17%) ,H2so4
Used to contain: HCl (max 35%), NaOH (max 50%), NaCLO (max 10%), PAC (max 17%), H2SO4 etc
Media (density) : (1155 Kg/m3), Hydrochloric Acid (1150 Kg/m3), Sulfate, Nitrate (1152 Kg/m3), Phosphate (1151 Kg/m3), Hydrofluoric Acid (1132 Kg/m3), Battery Fluid (1135 Kg/m3), Chloride (1135 Kg/m3), Ferric Chloride Solution (1130 Kg/m3), Sodium Hypochlorite (1130 Kg/m3), Sulfurous Acid (1030 Kg/m3)
processing/storing; aluminum sulfate, ammonium sulfate, calcium chloride, ethylene glycol, ferric chloride, ferric sulfate, ferrous sulfate, hydrochloric acid, hydrofluoric acid, hydrofluosilicic acid, hydrogen peroxide, magnesium chloride, phosphoric acid, polymers, potassium hydroxide, or just plain water and we'll design the vessel(s) you require.
Horizontal / Vertical Storage HCL Acid Tanks Steel Lined LDPE 120000 Liters
For Storage Bleach, Hydrochloric Acid, Ferric Chloride, Oilfield Chemicals, Corrosive Wastes And Other Hazardous Cargoes.
Steel ( 6 mm -8mm ) Lined PE Plastic 7042 (16mm - 25 mm ) storage tank
Specification | General PTFE thickness and negative pressure-resistance | The thickness of PTFE wall required to resist-0.1MPA pressure when the temperature is less than 120degree, | |
DN25 | 2mm | -0.08Mpa | 3mm(L≤3000mm) |
DN32 | 2mm | -0.075Mpa | 3mm(L≤3000mm) |
DN40 | 2.5mm | -0.075Mpa | 4mm(L≤3000mm) |
DN50 | 2.5mm | -0.06Mpa | 5mm(L≤3000mm) |
DN65 | 2.5mm | -0.05Mpa | 8mm(L≤1000mm) |
DN80 | 3mm | -0.05Mpa | 10mm(L≤1000mm) |
DN100 | 3mm | -0.04Mpa | 13mm(L≤1000mm) |
DN125 | 4mm | -0.03Mpa | 13mm(L≤1000mm) |
DN150 | 4mm | -0.025Mpa | 13mm(L≤1000mm) |
DN200 | 5mm | -0.02Mpa | 15mm(L≤1000mm) |
Specifications:
Nominal Diameter (mm/in. ): DN15-DN600 (NPS 1/2-NPS 24)
Operating temperature: -20-180 degree
Operating pressure: -0.09MPa-1.6MPa (-0.9bar-16bar)
Pipe: Seamless steel.
Flange: ASME B16.5 Class 150 Flange options: HG, GB, JB, JIS, BS, DIN, ANSI, ASTM
Special pieces of specific or non standard size can be manufactured on request.
Carbon steel 45/90degree ptfe lined elbow
Operating temperature: -20-180
Operating pressure: -0.09MPa-1.6MPa
Carbon steel 45/90degree ptfe lined elbow
1. Positive pressure: It shall adopt steel components according to different technical requirements, and the thickness of PTFE wall shall be over 2mm. If the temperature is less than 100 degree, the production length shall be less than 6m; And if the temperature exceeds 100 degree, the length shall be less than 3m.
2. Negative pressure: Design according to different ambient conditions of the users
PTFE lined 90° elbow | Unit mm | ||||||||
Nominal diameter | Specification of balled iron T | Raised face A | Central height C1 | Inside diameter D1 | PTFE thickness | out side diameter of flange D | Diameter of bolt circle K | Thickness of flange C | |
DN(mm) | NPS(inch) | ||||||||
DN15 | 1/2 | 34 | 40 | 80 | 15 | 5 | 90 | 65 | 11 |
DN20 | 3/4 | 38 | 45 | 90 | 18 | 5 | 100 | 75 | 11 |
DN25 | 1 | 42 | 60 | 92 | 22 | 5 | 110 | 85 | 12 |
DN32 | 1 1/4 | 48 | 70 | 100 | 28 | 5 | 130 | 100 | 13 |
DN40 | 1 1/2 | 57 | 80 | 112 | 38 | 5 | 140 | 110 | 14 |
DN50 | 2 | 68 | 95 | 117 | 48 | 5 | 155 | 125 | 14 |
DN65 | 2 1/2 | 89 | 115 | 135 | 63 | 8 | 175 | 145 | 16 |
DN80 | 3 | 108 | 130 | 150 | 78 | 8 | 190 | 160 | 16 |
DN100 | 4 | 114 | 150 | 150 | 87 | 8 | 210 | 180 | 18 |
DN125 | 5 | 140 | 180 | 190 | 110 | 8 | 240 | 210 | 20 |
DN150 | 6 | 168 | 205 | 230 | 135 | 10 | 275 | 240 | 20 |
DN200 | 8 | 219 | 260 | 305 | 180 | 10 | 330 | 295 | 20 |
DN250 | 10 | 273 | 315 | 380 | 230 | 12 | 385 | 350 | 23 |
DN300 | 12 | 325 | 365 | 420 | 280 | 12 | 435 | 400 | 23 |
Key words:
ptfe lined pipe fittings | ptfe lined tee | ptfe lined reducer | ptfe lined elbow | ptfe lined cross |
ptfe lined pipe and fittings | ptfe lined90degree elbow | ptfe lined 45 degrdd elbow | ptfe lined ECC reducer | ptfe lined CON reducer |
ptfe lined equal tee | ptfe lined reduce tee | ptfe lined unequal tee | ptfe lined pipe | ptfe lined fittings |
ptfe lined carbon steel pipe fittings | ptfe lined carbon steel tee | ptfe lined carbon steel reducer | ptfe lined carbon steel elbow | ptfe lined carbon steel cross |
PTFE pipe | PTFE lined pipe(Australia) | Resistant Stainless Steel Pipe | Resistant Steel Pipe | Carbon seamless steel pipe |
Anti Corrosion Pipe Fittings Lined | PTFE lining fittings | PTFE lined piping | straight tee | PTFE lined bends |
The chemical compatibility of LDPE and HDPE on this chart is tested at 20°C: and 50°C: for 7 days and 30 days (if applicable) with constant exposure.
LDPE & HDPE resistance listed by chemical | |
1.4-dioxane | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE at 50°C: shows some effect after 7 days. |
Acetaldehyde | LDPE / HDPE at 20°C: little or no damage after 30 days. HDPE at 50°C: shows some effect after 7 days. LDPE at 50°C: immediate damage may occur. |
Acetic Acid 5 % | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Acetic Acid, glacial 50% | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE at 50 °C: immediate damage may occur. |
Acetone | LDPE / HDPE at 20°C-50°C: damage may occur. Not recommended for continuous use. |
Allyl Alcohol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Aluminum salts | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Amino acids | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ammonia | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ammonium carbonate saturated | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ammonium phosphate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ammonium sulphate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Amyl chloride | HDPE at 20°C: shows some effect after 7 days. HDPE at 50°C & LDPE at 20°C-50°C: immediate damage may occur. Not recommended for continuous use. |
Aniline | LDPE / HDPE at 20°C: little or no damage after 30 days. HDPE at 50°C: shows some effect after 7 days. |
Benzene | LDPE / HDPE at 20°C-50°C: damage may occur. Not recommended for continuous use. |
Benzyl alcohol | LDPE / HDPE at 50°C: immediate damage may occur. HDPE at 20°C: shows some effect after 7 days. |
Boric acid | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Bromine | LDPE / HDPE at 50°C: immediate damage may occur. HDPE at 20°C: shows some effect after 7 days. |
Butyric acid | LDPE / HDPE at 50°C: immediate damage may occur. HDPE at 20°C: shows some effect after 7 days. |
Calcium chloride | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Calcium hydroxide saturated | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Carbon tetrachloride | HDPE at 20°C: shows little or no damage after 30 days. LDPE at 20°C & HDPE at 50°C: show some effect after 7 days. LDPE at 50°C: not recommended. |
Chlorine 10% in water | LDPE / HDPE at 20°C: shows little or no damage after 30 days. LDPE at 50°C: shows damage and is not recommended. |
Chlorobenzene | Immediate damage may occur. Not recommended for continuous use. |
Chloroform | LDPE / HDPE at 20°C: show some effect after 7 days. LDPE / HDPE at 50°C: immediate damage may occur. Not recommended for continuous use. |
Chromic acid 10% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Chromic acid 50% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Citric acid 10% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Cresol | HDPE at 20°C: shows some effect after 7 days. LDPE at 20°C-50°C & HDPE at 50°C: show immediate damage. Not recommended for continuous use. |
Cyclohexane | LDPE / HDPE at 50°C: immediate damage may occur. LDPE / HDPE at 20°C: show some effect after 7 days. |
Diethyl ketone | LDPE / HDPE at 20°C-50°C: damage may occur. Not recommended for continuous use. |
Dimethylsulfoxide | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ethanol 95% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ethyl acetate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ethyl benzene | HDPE at 20°C: shows some effect after 7 days. LDPE at 20°C-50°C & HDPE at 50°C: show immediate damage. Not recommended for continuous use. |
Ethylene glycol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ethylene oxide | HDPE at 20°C: shows little or no damage after 30 days. LDPE at 20°C: and LDPE/ HDPE at 50°C: show some effect after 7 days. |
Ferric chloride | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Fluoride | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Fluorine | HDPE at 20°C: shows little or no damage after 30 days. LDPE at 20°C: shows some effect after 7 days. Not recommended at 50°C. |
Formaldehyde 10% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Formaldehyde 40% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Glycerol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hexane | HDPE at 20°C: shows little or no damage after 30 days continuous use. HDPE at 50 °C: shows some effect after 7 days. LDPE not recommended at any temperature. |
Hydrochloric acid 20% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrochloric acid 35% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrochloric acid 5% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrocyanic acid | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrofluoric acid | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrofluoric acid 4% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrofluoric acid 48% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrogen peroxide 3% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrogen peroxide 30% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Isobutyl alcohol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Isopropyl alcohol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Kerosene | LDPE / HDPE at 20°C: show some effect after 7 days. LDPE / HDPE not recommended at 50°C, as immediate damage may occur. |
Lactic Acid 10 % | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Lactic Acid 90 % | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Lead acetate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Methanol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Methyl ethyl ketone | Immediate damage may occur. Not recommended for continuous use. |
Methyl propyl ketone | HDPE at 20°C: shows some effect after 7 days. LDPE at 20°C-50°C & HDPE at 50°C: Immediate damage may occur. Not recommended for continuous use. |
Methylene chloride | HDPE at 20°C: shows some effect after 7 days. LDPE at 20°C-50°C & HDPE at 50°C: Immediate damage may occur. Not recommended for continuous use. |
Mineral oil | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE at 50°C: may show immediate damage and is not recommended. |
n-amyl acetate | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE at 50°C: shows some effect after 7 days or constant exposure. |
n-butyl alcohol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Nitric acid 50 % | LDPE at 20°C: shows little or damage after 30 days. HDPE at 20°C & LDPE at 50°C: show effect after 7 days. HDPE at 50°C: shows immediate damage and is not recommended. |
Nitric acid 70 % | LDPE / HDPE at 20°C: show some effect after 7 days. LDPE / HDPE at 50°C: show immediate damage. Not recommended. |
n-octane | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Oleic acid | HDPE at 20°C-50°C: little or no damage after 30 days. LDPE at 20°C-50°C: shows immediate damage and is not recommended. |
Oxalic acid | LDPE at 20°C: shows some effect after 7 days. HDPE at 20°C and LDPE / HDPE at 50°C: shows little/ no damage after 30 days. |
Ozone | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE / HDPE at 50°C: show immediate damage. Not recommended. |
Perchloric acid | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE / HDPE at 50°C: show immediate damage. Not recommended. |
Perchloric ethylene | LDPE / HDPE at 20°C-50°C: show immediate damage. Not recommended. |
Phenol | LDPE / HDPE at 20°C-50°C: show immediate damage. Not recommended. |
Phosphoric acid 10% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Phosphoric acid 85% | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE at 50°C: shows immediate damage and is not recommended. |
Phosphorous trichloride | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE at 50°C: has no data available. HDPE at 50°C: shows some effect after 7 days. |
Potassium carbonate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Potassium hydroxide 5 % | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Potassium hydroxide concentrated | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Potassium permanganate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Propylene glycol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Pyridine | Immediate damage may occur. Not recommended for continuous use. |
Salicylic acid, saturated | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Silver acetate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Silver nitrate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sodium carbonate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sodium chloride, saturated | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sodium dichromate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sodium hydroxide 1% | LDPE at 20°C-50°C: shows little or no damage after 30 days. HDPE at 20°C-50°C: shows some effect after 7 days. |
Sodium hydroxide 50% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sodium hypochlorite 15% | HDPE at 20°C-50°C: little or no damage after 30 days. LDPE at 20°C: is suitable but at 50°C: shows some effect after 7 days. |
Sodium nitrate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sodium sulphate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sucrose | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sulfuric acid 20% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sulfuric acid 6% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sulfuric acid 60% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sulfuric acid 98% | LDPE at 20°C-50°C: shows little or no damage after 30 days. HDPE at 20°C: shows effect after 7 days. Not recommended for use at 50°C. |
Tannic acid | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Tetrahydrofuran | LDPE / HDPE at 20°C: show some effect after 7 day of constant exposure. LDPE / HDPE at 50°C: show immediate damage. Not recommended. |
Toluene | LDPE at 20°C: show some effect after 7 day of constant exposure. HDPE at 20°C-50°C & LDPE at 50°C: show immediate damage. Not recommended. |
Trichloracetic acid | LDPE / HDPE at 20°C: show some effect after 7 day of constant exposure. LDPE / HDPE at 50°C: show immediate damage. Not recommended. |
Trichlorethane | Immediate damage may occur. Not recommended for continuous use. |
Turpentine oil | LDPE / HDPE at 20°C: show some effect after 7 days. LDPE / HDPE at 50°C: show immediate damage. Not recommended. |
Urea | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Xylene | HDPE at 20°C: shows some effect after 7 day of constant exposure. LDPE at 20-50°C and HDPE at 50°C: show immediate damage. Not recommended. |
Zinc chloride | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Advantages And Disadvantages of Different Material Storage T8 T14 PE / PTFE Lined ISO Tank Container for Electronic Grade Hydrogen Peroxide (H₂O₂) DTAU2509016 DTAU2509021 DTAU2509037
6PCS T7 T14 PE Lined ISO Tank Container for HCL, PAC Hydrochloric Acid / Chemical Poly Aluminum Chloride 21KL To Vietnam road transport type PE Lined Tank Used to contain: HCl , NaOH , PAC , H2SO4(max 98%) etc. Tank Capacity: 21,000 Liters 21m3 Steel sheet 6mm, head 6mm Liner thickness: 16mm PE 20 FT TANK (EMPTY AND NEW TANKS) HCDA2505016 HCDA2505021 HCDA2505037 HCDA2505042 HCDA2505058 HCDA2505063
3 Units PE Lined T7 T8 T14 ISO Tank Container for DHF,HCL,KOH,H2O2 Hydrofluoric Acid/ Hydrochloric Acid/ Potassium Hydroxide / Hydrogen Peroxide Export To India DTAU2508010 DTAU2508025 DTAU2508030 20FT TANK CONTAINER (EMPTY AND NEW TANKS)
20PCS UN 3394 3399 Portable Tanks C-480 TMA Cylinders to USA PORTABLE TANK (EMPTY AND NEW TANKS) C-480 CYLINDER HS:860900.00(USA) Adr/Rid Organometallic Substance, Liquid, Water- Reactive C-480 Saddle Type Portable Tank, tank capacity 1880L KS1880-T21 Portable Tanks ASME Test DATA Report(C250051-C250070) BV Certificate No.:IIC-BVCT2570036S KSVU 250051 -70 Max. gross mass : 4000 kg Tare : 1050 kg Payload : 2950 kg
4 Units T14 ISO Tank Container PE Lined for Hydrofluoric HF Hydrochloric Acid HCL, Ferric Chloride Potassium Hydroxide KOH Tank Container Export To India DTAU2502011 DTAU2502027 DTAU2502032 DTAU2502048 20 FT TANK CONTAINER FOR HYDROCHLORIC ACID UN1789 HCL, HYDROFLUORIC ACID UN1790 HF ACID CARON STEEL AND LINED WITH 16MM LLDPE TANKS CAPACITY 21 KL FOR ROAD INLAND MOVEMENTS SHELL THICKNESS 6MM ,HEAD 8MM LLDPE 16MM, TOP UNLOADING TARE WEIGHT 5200KG 1UNIT 20FT TANK CONTAINER FOR UN1814 KOH POTASSIUM HYDROXIDE 45% SOLUTION DISH HEAD TYPE TANK CAPACITY: 19000LITERS FOR ROAD INLAND MOVEMENTS SHELL THICKNESS 6MM ,HEAD 8MM LLDPE 16MM, BOTTOM UNLOADING TARE WEIGHT 5300KG 1UNIT 20FT TANK CONTAINER FOR UN2014 H2O2 HYDROGEN PEROXIDE 31% SOLUTION DISH HEAD TYPE TANK CAPACITY: 19000LITERS FOR ROAD INLAND MOVEMENTS SHELL THICKNESS 6MM ,HEAD 8MM LLDPE 16MM, BOTTOM UNLOADING TARE WEIGHT 5300KG 2UNITS
Steel Lined PE Plastic ISO Tank for Hydrochloric Acid HCL12KL,15KL/16KL/19KL/22KL To Vietnam Description of goods Quantity N.W PE LINED STEEL TANK 5100X 2350 X 1400MM / 12.5M3 (EMPTY AND NEW TANKS) MODEL: DTA5212 HS CODE : 7309000000 、6300KGS PE LINED STEEL TANK 6040 X 2400 X 1600MM / 15.8M3 (EMPTY AND NEW TANKS) MODEL: DTA5215 HS CODE : 7309000000 1 3650KG PE LINED STEEL TANK 7190 X 2300X 1300MM / 16.2M3 (EMPTY AND NEW TANKS) MODEL: DTA5316 HS CODE : 7309000000 、4350KG PE LINED STEEL TANK 8520 X 2260 X 1350MM / 19.5M3 (EMPTY AND NEW TANKS) MODEL: DTA5319 HS CODE : 7309000000 、4850KG 20 FT TANK CONTAINER 6058X2438X2591MM / 22.8M3 (EMPTY AND NEW TANKS) MODEL: DTAU2501015 、5800KG
1000L SS304 Stainless Steel Lined PE Plastic Tank for Hydrochloric Acid to GUAYAQUIL, EC STORAGE TANK 304 STAINLESS STEEL LINED PLASTIC TANK VERTICAL TANK STAINLESS STEEL 304 THICKNESS 5MM+PE 16MM CAPACITY: 1,000 L RESIST 15%~38% HYDROCHLORIC ACID HS CODE:730900
20Units UN T21 Portable Tank Container 1880L Cylinder For TEAL Metal Alkyls UN3394 UN3399 to USA with 30pcs Spare PSV RELIEF VALVES SF/A412F-25P(3B) Manufacturer (SHENYANG XINGUANG VALVE ) KS1880-T21 Portable Tanks Max. gross mass : 4000 kg Tare : 1050 kg Payload : 2950 kg KSVU240016 -KSVU240035 Adr/Rid Organometallic Substance, Liquid, Water- Reactive C-480 Saddle Type Portable Tank, tank capacity 1880L
6 Sets Thermal Insulated LLDPE Lined Tanks 25KL for Sodium Hypochlorite Hydrochloric Acid To Saudi Arabia Lined PE Tanks 6604Gallon For Truck Trailer mounted FROM WUHAN PORT CHINA TO DAMMAM, SAUDI ARABIA BY SEA. + Port of loading : WUHAN PORT + Port of unloading :DAMMAM SAUDI ARABIA
2 Units T14 Hydrofluoric Hydrochloric Acid UN1789 UN1790 ISOTank Container Road Transport For ASCOR 20FT Tank Container (EMPTY AND NEW TANKS) FOR HYDROCHLORIC ACID UN1789 HCL HYDROFLUORIC ACID HF ACID UN1790 CARBON STEEL AND LINED WITH 16MM LLDPE DTAU2404015, DTAU2404020
5 Units Keystone Vessel T21 TEAL UN Portable Tank C480 Cylinder To SAUDI ARABIA KS1880-T21 Portable Tanks Max. gross mass : 4000 kg Tare : 1050 kg Payload : 2950 kg KSVU2400114 KSVU2400120 KSVU2400135 KSVU2400140 KSVU2400156
7 Units T14 Hydrofluoric Acid ISO Tank Container For Export to India 20FT TANK CONTAINER (EMPTY AND NEW TANKS) 20 FT TANK CONTAINER FOR HYDROFLUORIC ACID UN1790 HF ACID, CARON STEEL AND LINED WITH 16 MM LLDPE TANKS CAPACITY 21 KL COUNTRY OF ORIGIN : CHINA MARKING TANK NO.: DTAU2407014 DTAU2407020 DTAU2407035 DTAU2407040 DTAU2407056 DTAU2407061 DTAU2407077
2 UNITS 20FT Sodium Cyanide ISO Tank Container for West Africa Global Mine Operations 20FT Tank Container for Sodium Cyanide carbon steel and lined with 16mm LLDPE Specialized Tank Container, Sodium Cyanide Tank T6, Capacity 20000litre Hydrochloric acid with the concentration of 1789 (38%) 2X20TK DTAU2024611 DTAU2024627
PE Lined 20FT ISOTank Container For HCL Acid KOH 18KL To Vietnam (EMPTY AND NEW TANKS) TANK CAPACITY: 18M3 DTAU2407082
20Ft Stainless Steel Tank Container For Water Road Transport TO PORT OF SPAIN, TT 20FT Tank Container For store water capacity 25KL DTAU2407098