Availability: | |
---|---|
Quantity: | |
Shanghai, China
3000
T/T
Tri Axles Hydrofluoric Acid Tanker Trailer ( Hydrochloride Acid HCL 35% Tank Capacity 33,000L Muriatic Acid )
(3 axles Semi Trailer 28900Liters,32400liters,33000L Steel Lined LLDPE Acid Tank WEAK SULFURIC ACID 60% ,20%,6% ) Strong SULFURIC ACID 98% at 20C degree.
Hydrochloric Acid Tank Semi trailer 3 axles 29900Liters,32400liters )
Ask for better price
Cell +8615271357675
The pictures are for your reference only.
Hydrochloric acid tank semitrailer 2axles 19900Liters,19900Liters,22400liters,23800liters
Tank volume: 22.4 cbm: hydrochloric acid, dilute sulphuric acid ,acetic acid, acrylic acid
tank body effective volume: 23.82 cubic metres,
transport : hydrochloride, hydrogen chlorate, sodium hydroxide,acrylic
acetic acid, glacial acetic acid, hydrogen peroxide
Propionic acid, ammonia,NH3·H2O
Dangerous Acid Tank Trailer Description of Dilute Sulfuric Acid Tank Trailer Dangerous Acid Tank Trailer The trailer for dilute sulphuric acid transportation is specially designed for the transportation of dilute sulphuric acid. It has a large volume of 22 cmb
Dilute Sulfuric Acid Tank Trailer Dangerous Acid Tank Trailer
Description of Dilute Sulfuric Acid Tank Trailer Dangerous Acid Tank Trailer
The trailer for dilute sulphuric acid transportation is specially designed for the transportation of dilute sulphuric acid. It has a large volume of 22 cmb. In order to ensure safety and stability, the inner lining of the tank is 16 mm thick and the outer layer is made of 6 mm carbon steel, which ensures the safety of transportation.
Even a certain degree of bumping will not lead to tank cracking, and sulfuric acid leakage.
The tank also has a wave-proof plate inside, which reduces the greater pressure caused by starting or braking of the trailer and further strengthens the safety performance of the trailer.
Advantages of Dilute Sulfuric Acid Tank Trailer Dangerous Acid Tank Trailer
Integral Forming
The tank is handled by automatic reeling and rotational moulding. The flange of the nozzle is solid and has to be cut by a puncher. There is no any welded seam in the tank and the lining of the flange. Hence, both the tank and the flange are durable and clean. Any acid or alkali with various concentrations can be resisted.
Waveproof
There are many wave-proof plates inside the tank body, which ensure the safety and stability of the tank body and minimize the impact during start-up and braking.
Specification
Main Dimensions | |
Overall Dimension | 11800x2500x3250 |
Tare Weight | 10900 |
Loading Capacity | 45ton |
Tank Body | |
Shape | Mono block Cylinder |
Total Volume (m3) | 22cmb |
Tanker Body Material | 6 mm carbon steel |
End Plate | 6 mm carbon steel |
Inner Lining | 16 mm plastics |
Manhole Cover | ∮500mm; 2 sets with 2 breather valve; steel manhole cover with plastic lining |
Discharging Valve | 2 sets ∮100mm discharging valve, stainless made |
Safety Valve | 1 set of safety valve |
Discharging Pipe | 4" rubber hose, 2pcs, 6m long |
Chassis | |
Axle | 3pcs BPW axle, 13Ton capacity |
Landing Gear | JOST brand Two-speed; manual operating; heavy duty landing gear |
King Pin | JOST brand 2" bolt-in king pin |
Suspension | Mechanical suspension with leaf spring |
Braking System | WABCO RE 6 relay valve; T30/30 Spring brake chamber; 40L air tanks |
Wheel Rim | 9.0-22.5 wheel rim, 12 pieces |
Tire | 12R22.5 tubeless tire , 12 pieces |
Painting | Complete Chassis sand blasting to clean rust, 1 coat of anticorrosive prime, 2 coats of final paint |
Accessories | One standard tool box, one spare tyre and carrier |
Hydrochloric acid tank semitrailer 2axles 19900Liters,19900Liters,22400liters,23800liters
Tank volume: 22.4 cbm,
medium: hydrochloric acid, dilute sulphuric acid (density is 1260 kilograms/cubic meter),
acetic acid, acrylic acid (medium density of 1140 kilograms/cubic meter)
Tank body effective volume: 23.82 cubic metres,
transport media name: hydrochloride, hydrogen chlorate, sodium hydroxide,
acrylic (media density are for 1190 kilograms/cubic metres),
acetic acid, glacial acetic acid, hydrogen peroxide (media density are for 1140 kilograms/cubic metres)
Propionic acid, (density for 1110 kilograms/cubic metres),
ammonia, (NH3·H2Odensity for 1090 kilograms/cubic metres),
Hydrochloric acid tank semitrailer 2axles 19900Liters,19900Liters,22400liters,23800liters
Fuwa 13tone axles,
Hydrochloric acid tank transport semi-trailer
Customization, Cost Control Built How You Want it, at a Price You Can
Afford. for sale call:+86-152 -7135-7675
chemical resistance of LLDPE Cell / :+8615271357675
www.truckinchina.com
The chemical compatibility of LDPE and HDPE on this chart is tested at 20°C: and 50°C: for 7 days and 30 days (if applicable) with constant exposure.
LDPE & HDPE resistance listed by chemical | |
1.4-dioxane | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE at 50°C: shows some effect after 7 days. |
Acetaldehyde | LDPE / HDPE at 20°C: little or no damage after 30 days. HDPE at 50°C: shows some effect after 7 days. LDPE at 50°C: immediate damage may occur. |
Acetic Acid 5 % | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Acetic Acid, glacial 50% | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE at 50 °C: immediate damage may occur. |
Acetone | LDPE / HDPE at 20°C-50°C: damage may occur. Not recommended for continuous use. |
Allyl Alcohol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Aluminum salts | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Amino acids | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ammonia | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ammonium carbonate saturated | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ammonium phosphate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ammonium sulphate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Amyl chloride | HDPE at 20°C: shows some effect after 7 days. HDPE at 50°C & LDPE at 20°C-50°C: immediate damage may occur. Not recommended for continuous use. |
Aniline | LDPE / HDPE at 20°C: little or no damage after 30 days. HDPE at 50°C: shows some effect after 7 days. |
Benzene | LDPE / HDPE at 20°C-50°C: damage may occur. Not recommended for continuous use. |
Benzyl alcohol | LDPE / HDPE at 50°C: immediate damage may occur. HDPE at 20°C: shows some effect after 7 days. |
Boric acid | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Bromine | LDPE / HDPE at 50°C: immediate damage may occur. HDPE at 20°C: shows some effect after 7 days. |
Butyric acid | LDPE / HDPE at 50°C: immediate damage may occur. HDPE at 20°C: shows some effect after 7 days. |
Calcium chloride | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Calcium hydroxide saturated | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Carbon tetrachloride | HDPE at 20°C: shows little or no damage after 30 days. LDPE at 20°C & HDPE at 50°C: show some effect after 7 days. LDPE at 50°C: not recommended. |
Chlorine 10% in water | LDPE / HDPE at 20°C: shows little or no damage after 30 days. LDPE at 50°C: shows damage and is not recommended. |
Chlorobenzene | Immediate damage may occur. Not recommended for continuous use. |
Chloroform | LDPE / HDPE at 20°C: show some effect after 7 days. LDPE / HDPE at 50°C: immediate damage may occur. Not recommended for continuous use. |
Chromic acid 10% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Chromic acid 50% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Citric acid 10% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Cresol | HDPE at 20°C: shows some effect after 7 days. LDPE at 20°C-50°C & HDPE at 50°C: show immediate damage. Not recommended for continuous use. |
Cyclohexane | LDPE / HDPE at 50°C: immediate damage may occur. LDPE / HDPE at 20°C: show some effect after 7 days. |
Diethyl ketone | LDPE / HDPE at 20°C-50°C: damage may occur. Not recommended for continuous use. |
Dimethylsulfoxide | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ethanol 95% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ethyl acetate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ethyl benzene | HDPE at 20°C: shows some effect after 7 days. LDPE at 20°C-50°C & HDPE at 50°C: show immediate damage. Not recommended for continuous use. |
Ethylene glycol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ethylene oxide | HDPE at 20°C: shows little or no damage after 30 days. LDPE at 20°C: and LDPE/ HDPE at 50°C: show some effect after 7 days. |
Ferric chloride | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Fluoride | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Fluorine | HDPE at 20°C: shows little or no damage after 30 days. LDPE at 20°C: shows some effect after 7 days. Not recommended at 50°C. |
Formaldehyde 10% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Formaldehyde 40% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Glycerol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hexane | HDPE at 20°C: shows little or no damage after 30 days continuous use. HDPE at 50 °C: shows some effect after 7 days. LDPE not recommended at any temperature. |
Hydrochloric acid 20% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrochloric acid 35% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrochloric acid 5% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrocyanic acid | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrofluoric acid | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrofluoric acid 4% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrofluoric acid 48% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrogen peroxide 3% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrogen peroxide 30% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Isobutyl alcohol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Isopropyl alcohol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Kerosene | LDPE / HDPE at 20°C: show some effect after 7 days. LDPE / HDPE not recommended at 50°C, as immediate damage may occur. |
Lactic Acid 10 % | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Lactic Acid 90 % | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Lead acetate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Methanol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Methyl ethyl ketone | Immediate damage may occur. Not recommended for continuous use. |
Methyl propyl ketone | HDPE at 20°C: shows some effect after 7 days. LDPE at 20°C-50°C & HDPE at 50°C: Immediate damage may occur. Not recommended for continuous use. |
Methylene chloride | HDPE at 20°C: shows some effect after 7 days. LDPE at 20°C-50°C & HDPE at 50°C: Immediate damage may occur. Not recommended for continuous use. |
Mineral oil | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE at 50°C: may show immediate damage and is not recommended. |
n-amyl acetate | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE at 50°C: shows some effect after 7 days or constant exposure. |
n-butyl alcohol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Nitric acid 50 % | LDPE at 20°C: shows little or damage after 30 days. HDPE at 20°C & LDPE at 50°C: show effect after 7 days. HDPE at 50°C: shows immediate damage and is not recommended. |
Nitric acid 70 % | LDPE / HDPE at 20°C: show some effect after 7 days. LDPE / HDPE at 50°C: show immediate damage. Not recommended. |
n-octane | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Oleic acid | HDPE at 20°C-50°C: little or no damage after 30 days. LDPE at 20°C-50°C: shows immediate damage and is not recommended. |
Oxalic acid | LDPE at 20°C: shows some effect after 7 days. HDPE at 20°C and LDPE / HDPE at 50°C: shows little/ no damage after 30 days. |
Ozone | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE / HDPE at 50°C: show immediate damage. Not recommended. |
Perchloric acid | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE / HDPE at 50°C: show immediate damage. Not recommended. |
Perchloric ethylene | LDPE / HDPE at 20°C-50°C: show immediate damage. Not recommended. |
Phenol | LDPE / HDPE at 20°C-50°C: show immediate damage. Not recommended. |
Phosphoric acid 10% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Phosphoric acid 85% | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE at 50°C: shows immediate damage and is not recommended. |
Phosphorous trichloride | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE at 50°C: has no data available. HDPE at 50°C: shows some effect after 7 days. |
Potassium carbonate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Potassium hydroxide 5 % | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Potassium hydroxide concentrated | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Potassium permanganate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Propylene glycol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Pyridine | Immediate damage may occur. Not recommended for continuous use. |
Salicylic acid, saturated | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Silver acetate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Silver nitrate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sodium carbonate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sodium chloride, saturated | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sodium dichromate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sodium hydroxide 1% | LDPE at 20°C-50°C: shows little or no damage after 30 days. HDPE at 20°C-50°C: shows some effect after 7 days. |
Sodium hydroxide 50% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sodium hypochlorite 15% | HDPE at 20°C-50°C: little or no damage after 30 days. LDPE at 20°C: is suitable but at 50°C: shows some effect after 7 days. |
Sodium nitrate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sodium sulphate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sucrose | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sulfuric acid 20% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sulfuric acid 6% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sulfuric acid 60% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sulfuric acid 98% | LDPE at 20°C-50°C: shows little or no damage after 30 days. HDPE at 20°C: shows effect after 7 days. Not recommended for use at 50°C. |
Tannic acid | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Tetrahydrofuran | LDPE / HDPE at 20°C: show some effect after 7 day of constant exposure. LDPE / HDPE at 50°C: show immediate damage. Not recommended. |
Toluene | LDPE at 20°C: show some effect after 7 day of constant exposure. HDPE at 20°C-50°C & LDPE at 50°C: show immediate damage. Not recommended. |
Trichloracetic acid | LDPE / HDPE at 20°C: show some effect after 7 day of constant exposure. LDPE / HDPE at 50°C: show immediate damage. Not recommended. |
Trichlorethane | Immediate damage may occur. Not recommended for continuous use. |
Turpentine oil | LDPE / HDPE at 20°C: show some effect after 7 days. LDPE / HDPE at 50°C: show immediate damage. Not recommended. |
Urea | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Xylene | HDPE at 20°C: shows some effect after 7 day of constant exposure. LDPE at 20-50°C and HDPE at 50°C: show immediate damage. Not recommended. |
Zinc chloride | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Tri Axles Hydrofluoric Acid Tanker Trailer ( Hydrochloride Acid HCL 35% Tank Capacity 33,000L Muriatic Acid )
(3 axles Semi Trailer 28900Liters,32400liters,33000L Steel Lined LLDPE Acid Tank WEAK SULFURIC ACID 60% ,20%,6% ) Strong SULFURIC ACID 98% at 20C degree.
Hydrochloric Acid Tank Semi trailer 3 axles 29900Liters,32400liters )
Ask for better price
Cell +8615271357675
The pictures are for your reference only.
Hydrochloric acid tank semitrailer 2axles 19900Liters,19900Liters,22400liters,23800liters
Tank volume: 22.4 cbm: hydrochloric acid, dilute sulphuric acid ,acetic acid, acrylic acid
tank body effective volume: 23.82 cubic metres,
transport : hydrochloride, hydrogen chlorate, sodium hydroxide,acrylic
acetic acid, glacial acetic acid, hydrogen peroxide
Propionic acid, ammonia,NH3·H2O
Dangerous Acid Tank Trailer Description of Dilute Sulfuric Acid Tank Trailer Dangerous Acid Tank Trailer The trailer for dilute sulphuric acid transportation is specially designed for the transportation of dilute sulphuric acid. It has a large volume of 22 cmb
Dilute Sulfuric Acid Tank Trailer Dangerous Acid Tank Trailer
Description of Dilute Sulfuric Acid Tank Trailer Dangerous Acid Tank Trailer
The trailer for dilute sulphuric acid transportation is specially designed for the transportation of dilute sulphuric acid. It has a large volume of 22 cmb. In order to ensure safety and stability, the inner lining of the tank is 16 mm thick and the outer layer is made of 6 mm carbon steel, which ensures the safety of transportation.
Even a certain degree of bumping will not lead to tank cracking, and sulfuric acid leakage.
The tank also has a wave-proof plate inside, which reduces the greater pressure caused by starting or braking of the trailer and further strengthens the safety performance of the trailer.
Advantages of Dilute Sulfuric Acid Tank Trailer Dangerous Acid Tank Trailer
Integral Forming
The tank is handled by automatic reeling and rotational moulding. The flange of the nozzle is solid and has to be cut by a puncher. There is no any welded seam in the tank and the lining of the flange. Hence, both the tank and the flange are durable and clean. Any acid or alkali with various concentrations can be resisted.
Waveproof
There are many wave-proof plates inside the tank body, which ensure the safety and stability of the tank body and minimize the impact during start-up and braking.
Specification
Main Dimensions | |
Overall Dimension | 11800x2500x3250 |
Tare Weight | 10900 |
Loading Capacity | 45ton |
Tank Body | |
Shape | Mono block Cylinder |
Total Volume (m3) | 22cmb |
Tanker Body Material | 6 mm carbon steel |
End Plate | 6 mm carbon steel |
Inner Lining | 16 mm plastics |
Manhole Cover | ∮500mm; 2 sets with 2 breather valve; steel manhole cover with plastic lining |
Discharging Valve | 2 sets ∮100mm discharging valve, stainless made |
Safety Valve | 1 set of safety valve |
Discharging Pipe | 4" rubber hose, 2pcs, 6m long |
Chassis | |
Axle | 3pcs BPW axle, 13Ton capacity |
Landing Gear | JOST brand Two-speed; manual operating; heavy duty landing gear |
King Pin | JOST brand 2" bolt-in king pin |
Suspension | Mechanical suspension with leaf spring |
Braking System | WABCO RE 6 relay valve; T30/30 Spring brake chamber; 40L air tanks |
Wheel Rim | 9.0-22.5 wheel rim, 12 pieces |
Tire | 12R22.5 tubeless tire , 12 pieces |
Painting | Complete Chassis sand blasting to clean rust, 1 coat of anticorrosive prime, 2 coats of final paint |
Accessories | One standard tool box, one spare tyre and carrier |
Hydrochloric acid tank semitrailer 2axles 19900Liters,19900Liters,22400liters,23800liters
Tank volume: 22.4 cbm,
medium: hydrochloric acid, dilute sulphuric acid (density is 1260 kilograms/cubic meter),
acetic acid, acrylic acid (medium density of 1140 kilograms/cubic meter)
Tank body effective volume: 23.82 cubic metres,
transport media name: hydrochloride, hydrogen chlorate, sodium hydroxide,
acrylic (media density are for 1190 kilograms/cubic metres),
acetic acid, glacial acetic acid, hydrogen peroxide (media density are for 1140 kilograms/cubic metres)
Propionic acid, (density for 1110 kilograms/cubic metres),
ammonia, (NH3·H2Odensity for 1090 kilograms/cubic metres),
Hydrochloric acid tank semitrailer 2axles 19900Liters,19900Liters,22400liters,23800liters
Fuwa 13tone axles,
Hydrochloric acid tank transport semi-trailer
Customization, Cost Control Built How You Want it, at a Price You Can
Afford. for sale call:+86-152 -7135-7675
chemical resistance of LLDPE Cell / :+8615271357675
www.truckinchina.com
The chemical compatibility of LDPE and HDPE on this chart is tested at 20°C: and 50°C: for 7 days and 30 days (if applicable) with constant exposure.
LDPE & HDPE resistance listed by chemical | |
1.4-dioxane | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE at 50°C: shows some effect after 7 days. |
Acetaldehyde | LDPE / HDPE at 20°C: little or no damage after 30 days. HDPE at 50°C: shows some effect after 7 days. LDPE at 50°C: immediate damage may occur. |
Acetic Acid 5 % | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Acetic Acid, glacial 50% | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE at 50 °C: immediate damage may occur. |
Acetone | LDPE / HDPE at 20°C-50°C: damage may occur. Not recommended for continuous use. |
Allyl Alcohol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Aluminum salts | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Amino acids | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ammonia | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ammonium carbonate saturated | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ammonium phosphate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ammonium sulphate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Amyl chloride | HDPE at 20°C: shows some effect after 7 days. HDPE at 50°C & LDPE at 20°C-50°C: immediate damage may occur. Not recommended for continuous use. |
Aniline | LDPE / HDPE at 20°C: little or no damage after 30 days. HDPE at 50°C: shows some effect after 7 days. |
Benzene | LDPE / HDPE at 20°C-50°C: damage may occur. Not recommended for continuous use. |
Benzyl alcohol | LDPE / HDPE at 50°C: immediate damage may occur. HDPE at 20°C: shows some effect after 7 days. |
Boric acid | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Bromine | LDPE / HDPE at 50°C: immediate damage may occur. HDPE at 20°C: shows some effect after 7 days. |
Butyric acid | LDPE / HDPE at 50°C: immediate damage may occur. HDPE at 20°C: shows some effect after 7 days. |
Calcium chloride | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Calcium hydroxide saturated | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Carbon tetrachloride | HDPE at 20°C: shows little or no damage after 30 days. LDPE at 20°C & HDPE at 50°C: show some effect after 7 days. LDPE at 50°C: not recommended. |
Chlorine 10% in water | LDPE / HDPE at 20°C: shows little or no damage after 30 days. LDPE at 50°C: shows damage and is not recommended. |
Chlorobenzene | Immediate damage may occur. Not recommended for continuous use. |
Chloroform | LDPE / HDPE at 20°C: show some effect after 7 days. LDPE / HDPE at 50°C: immediate damage may occur. Not recommended for continuous use. |
Chromic acid 10% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Chromic acid 50% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Citric acid 10% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Cresol | HDPE at 20°C: shows some effect after 7 days. LDPE at 20°C-50°C & HDPE at 50°C: show immediate damage. Not recommended for continuous use. |
Cyclohexane | LDPE / HDPE at 50°C: immediate damage may occur. LDPE / HDPE at 20°C: show some effect after 7 days. |
Diethyl ketone | LDPE / HDPE at 20°C-50°C: damage may occur. Not recommended for continuous use. |
Dimethylsulfoxide | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ethanol 95% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ethyl acetate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ethyl benzene | HDPE at 20°C: shows some effect after 7 days. LDPE at 20°C-50°C & HDPE at 50°C: show immediate damage. Not recommended for continuous use. |
Ethylene glycol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ethylene oxide | HDPE at 20°C: shows little or no damage after 30 days. LDPE at 20°C: and LDPE/ HDPE at 50°C: show some effect after 7 days. |
Ferric chloride | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Fluoride | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Fluorine | HDPE at 20°C: shows little or no damage after 30 days. LDPE at 20°C: shows some effect after 7 days. Not recommended at 50°C. |
Formaldehyde 10% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Formaldehyde 40% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Glycerol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hexane | HDPE at 20°C: shows little or no damage after 30 days continuous use. HDPE at 50 °C: shows some effect after 7 days. LDPE not recommended at any temperature. |
Hydrochloric acid 20% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrochloric acid 35% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrochloric acid 5% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrocyanic acid | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrofluoric acid | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrofluoric acid 4% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrofluoric acid 48% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrogen peroxide 3% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrogen peroxide 30% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Isobutyl alcohol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Isopropyl alcohol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Kerosene | LDPE / HDPE at 20°C: show some effect after 7 days. LDPE / HDPE not recommended at 50°C, as immediate damage may occur. |
Lactic Acid 10 % | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Lactic Acid 90 % | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Lead acetate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Methanol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Methyl ethyl ketone | Immediate damage may occur. Not recommended for continuous use. |
Methyl propyl ketone | HDPE at 20°C: shows some effect after 7 days. LDPE at 20°C-50°C & HDPE at 50°C: Immediate damage may occur. Not recommended for continuous use. |
Methylene chloride | HDPE at 20°C: shows some effect after 7 days. LDPE at 20°C-50°C & HDPE at 50°C: Immediate damage may occur. Not recommended for continuous use. |
Mineral oil | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE at 50°C: may show immediate damage and is not recommended. |
n-amyl acetate | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE at 50°C: shows some effect after 7 days or constant exposure. |
n-butyl alcohol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Nitric acid 50 % | LDPE at 20°C: shows little or damage after 30 days. HDPE at 20°C & LDPE at 50°C: show effect after 7 days. HDPE at 50°C: shows immediate damage and is not recommended. |
Nitric acid 70 % | LDPE / HDPE at 20°C: show some effect after 7 days. LDPE / HDPE at 50°C: show immediate damage. Not recommended. |
n-octane | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Oleic acid | HDPE at 20°C-50°C: little or no damage after 30 days. LDPE at 20°C-50°C: shows immediate damage and is not recommended. |
Oxalic acid | LDPE at 20°C: shows some effect after 7 days. HDPE at 20°C and LDPE / HDPE at 50°C: shows little/ no damage after 30 days. |
Ozone | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE / HDPE at 50°C: show immediate damage. Not recommended. |
Perchloric acid | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE / HDPE at 50°C: show immediate damage. Not recommended. |
Perchloric ethylene | LDPE / HDPE at 20°C-50°C: show immediate damage. Not recommended. |
Phenol | LDPE / HDPE at 20°C-50°C: show immediate damage. Not recommended. |
Phosphoric acid 10% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Phosphoric acid 85% | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE at 50°C: shows immediate damage and is not recommended. |
Phosphorous trichloride | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE at 50°C: has no data available. HDPE at 50°C: shows some effect after 7 days. |
Potassium carbonate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Potassium hydroxide 5 % | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Potassium hydroxide concentrated | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Potassium permanganate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Propylene glycol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Pyridine | Immediate damage may occur. Not recommended for continuous use. |
Salicylic acid, saturated | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Silver acetate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Silver nitrate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sodium carbonate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sodium chloride, saturated | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sodium dichromate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sodium hydroxide 1% | LDPE at 20°C-50°C: shows little or no damage after 30 days. HDPE at 20°C-50°C: shows some effect after 7 days. |
Sodium hydroxide 50% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sodium hypochlorite 15% | HDPE at 20°C-50°C: little or no damage after 30 days. LDPE at 20°C: is suitable but at 50°C: shows some effect after 7 days. |
Sodium nitrate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sodium sulphate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sucrose | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sulfuric acid 20% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sulfuric acid 6% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sulfuric acid 60% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sulfuric acid 98% | LDPE at 20°C-50°C: shows little or no damage after 30 days. HDPE at 20°C: shows effect after 7 days. Not recommended for use at 50°C. |
Tannic acid | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Tetrahydrofuran | LDPE / HDPE at 20°C: show some effect after 7 day of constant exposure. LDPE / HDPE at 50°C: show immediate damage. Not recommended. |
Toluene | LDPE at 20°C: show some effect after 7 day of constant exposure. HDPE at 20°C-50°C & LDPE at 50°C: show immediate damage. Not recommended. |
Trichloracetic acid | LDPE / HDPE at 20°C: show some effect after 7 day of constant exposure. LDPE / HDPE at 50°C: show immediate damage. Not recommended. |
Trichlorethane | Immediate damage may occur. Not recommended for continuous use. |
Turpentine oil | LDPE / HDPE at 20°C: show some effect after 7 days. LDPE / HDPE at 50°C: show immediate damage. Not recommended. |
Urea | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Xylene | HDPE at 20°C: shows some effect after 7 day of constant exposure. LDPE at 20-50°C and HDPE at 50°C: show immediate damage. Not recommended. |
Zinc chloride | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
2 Sets HOWO Offroad AWD 6x6 Mixing And Charging ANFO Explosive Trucks Delivery
10 Units Hydrochloric Acid HCL PE LINED ISO Tank Containers to Vietnam 20FT Tank Container PE Lined Tank Used to contain: HCl (max 35%), NaOH (max 50%), PAC (max 17%),H2SO4(max 94%) etc… Tank Capacity: 21,900 Liters Steel sheet 6mm, head 6mm Liner thickness: 16mm PE
17m3 , 22m3 Lined PE Tank Container for Hydrochloric Acid HCL to Vietnam 20FT TANK CONTAINER TANK VOLUME/ STEEL THICKNESS 22M3/ 6MM (SOC / EMPTY AND NEW TANKS) BRAND: DONG RUNZE MODEL: DRAU2308018 STORAGE TANK CONTAINER TANK FOR HCL CARGO TRUCK TANK VOLUME/STEEL THICKNESS:17M3/ 6MM ( EMPTY AND NEW TANKS) BRAND: DONG RUNZE MODEL: DTA5260 HS CODE : 7309000000
4 Sets Polyethylene Lined Steel Offshore T14 Tanks For Hydrochloric Acid Transport to Kazakhstan Marks DTAU2305012 DTAU2305028 DTAU2305033 DTAU2305049
80Units Metal Alky C480 UN Portable Tank T21 TEAL Cylinders to USA 80Units UN T21 Portable Tank Container 1880L Cylinder For TEAL Metal Alkyls UN3394 UN3399 to USA Adr/Rid Organometallic Substance, Liquid, Water- Reactive C-430 Saddle Type Portable Tank , tank capacity 1630L C-480 Saddle Type Portable Tank, tank capacity 1880L C-1980 TEAL TMGa ,TEGa,TMIn, TMAl DEAC Metal Alky C-1980 T21 Metal Alky 7495L
6 units Metal Alky C480 Portable Tank TEAL DEAC Cylinder for Singapore 360 DEG. ROTATABLE TOP FLANGE VALVE (KV-MTFF DN15 PN 40), 360 DEG. ROTATABLE TOP FLANGE VALVE (KV-MTFE DN20 PN 40) K4430 Gaskets
6 Sets Polyethylene Lined Steel Tanks 6600Gallon For Hydrochloric Acid Storage Transport Hydrochloric Acid (HCl) to SAU Chemical Factory This the 4th LOT HCL ,NaCLO Tanks For this SAU Chemical Facttory . The 1 st Order date will go back to Date 13-1-2021. CAST IRON STORAGE TANK FOR CHEMICAL MATERIALS STORAGE TANK CAPACITY: 25M3 HS CODE:7309000000
3 Sets Lined PE Tanks 6604Gallon For Storage Transport Sodium Hypochlorite to Saudi Arabia FROM WUHAN PORT CHINA TO DAMMAM, SAUDI ARABIA BY SEA. + Port of loading : WUHAN PORT + Port of unloading :DAMMAM CAST IRON STORAGE TANK FOR CHEMICAL MATERIALS STORAGE TANK CAPACITY: 25M3 HS CODE:730900 10.2x2.1x2.5*3 160.65cbm 3X40HQ
4PCS Power Take-off PTO FOR JMC TRANSMISSION MODEL DN3-7003-EC 6MT1420 to URUGUAY Sdq51/65 (Gearbox Power Take off For ISUZU QINGLING Transmission DN3-70030-E0, 6MT1420 PTO Assembly) HWP-G32/65CHQ ,32/65 PQ1
12PCS PTO Wanliyang Transmission Power Take-off For WLY6T40 WLY6TS40 to Mexico 1 PC SDQ211/60LGQ1 PTO FOR 6DS60T-D TO SAUDI ARABIA
2 Units Righ Hand Drive Shacman F3000 Hydro Excavators Truck Combined Vacuum Sewer Jetting to Suva Port Fiji Shacman F3000 Hydro Excavators Truck Sewer Jet Suction Units (RHD 13500L Sewage+4000L Clean Water ) PTO, transmission shaft, vacuum pump, tanker, hydraulic system and jetting pipe system. Combined Sewer Suction & Jetting Unit SZW Aluminium Alloy Liquid Water Ring Compressor Vacuum Pump XW-2800 VAC Flow 2800 M³/h ,1648 Cfm 46.7M3/min 75KW
6 Sets Lined PE Tanks 6604Gallon For Storage Transport Hydrochloric Acid (HCl) to Saudi Arabia FROM WUHAN PORT CHINA TO DAMMAM, SAUDI ARABIA BY SEA. Port of loading : WUHAN PORT + Port of unloading :DAMMAM DONG RUN ZE CAST IRON STORAGE TANK FOR CHEMICAL MATERIALS STORAGE TANK CAPACITY: 25M3 HS CODE:7309000000 9.7x2.2x2.5*6
2 Sets Hydrochloric Acid HCL Tank Container Lined PE 24m3 Trailer Mounted to Vietnam
10 Units 22KL 20FT ISO Steel Lined PE Hydrochloric Acid HCL Tank Container to Vietnam 20FT Tank Container PE Lined Tank Used to contain: HCl (max 35%), NaOH (max 50%), PAC (max 17%),H2SO4(max 94%) etc… Tank Capacity: 21,000 Liters Steel sheet 6mm, head 6mm Liner thickness: 16mm PE 01pc butterfly valve CS/F46 and 01pc ball valve CS/F46 DRAU2209015 DRAU2209020 DRAU2209036 DRAU2209041 DRAU2209057 DRAU2209062 DRAU2209078 DRAU2209083 DRAU2209099 DRAU2209102
2 Sets Hydrochloric Acid Hydrofluoric Acid Road transport 20Ft Tank Container to Chennai India DTAU2200916 DTAU2200921