Availability: | |
---|---|
Quantity: | |
Hino 700 6X4 Tanker Truck 350HP 15000~16000L ( For Chemical Acid Liquid ,Drink Water,Oil , Carbon Steel / Stainless Steel ,Lined PE Tank)
HINO 700 18cbm road tanker truck 350HP
15000 ~16000Litres
HINO 700Acid oil tanker truck for HCL, NaCIO acid Tank hydrochloric acid -HCL, dilute sulphuric acid WEAK SULFURIC ACID -H2SO4 ,sodium hypochlorite - NaCIO ,Caustic soda-NaOH
Customization, Cost and Control Built How You Want it, at a Price You Can Afford. for sale 86-152 -7135-7675 Steel Lined LDPE aslo for HCL(max 35%), NaOH (max 50%), NaCLO (max 10%), PAC (max 17%),H2SO4(60%,98%) ,HF ( 48%),H3PO4 (10%-85%),NH3. H2O,H2O2 (30%)
# | Engine model | Engine displacement | Engine power | Engine manufacturer | |||
1 | P11C-WB | 10520 cc | 10.5 L | 642 cuin | 240 kW | 327 hp | Shanghai Hino Engine Co., Ltd. |
Performance | ||
Fuel | diesel fuel | |
Maximum speed | 80 km/h | 50 mph |
ABS | have |
Weights and Ground pressure | |||
Curb weight | 14500 kg | 14.5 | |
Gross vehicle weight rating | 25000 kg | 25 t | 55,000 lbs |
Axle load distribution | 7000 kg / 18000 kg (tandem axle) 7 t / 18 t (tandem axle) 15,000 lbs / 40,000 lbs (tandem axle) |
Dimensions 9.42×2.5×3.97 | ||
Overall length | 9420 mm | |
Overall width | 2490 mm | |
Overall height | 3970 mm |
Undercarriage and Suspension | ||
Number of axles | 3 | |
Wheelbase | 3350+1410 mm | |
Front track | 2060 mm | 6′10″ |
Rear track | 1855 mm / 1855 mm | 6′2″ / 6′2″ |
Front overhang | 1460 mm | 4′10″ |
Rear overhang | 1290 mm | 4′3″ |
Angle of approach | 27° | |
Angle of departure | 39° | |
Leaf springs | 11/13,10/13 |
Tyres and Wheels | |
Number of tyres | 10 |
Tyres dimension | 11R22.5 |
Miscellaneous | |
Seating capacity | 2 |
Steering control | steering wheel |
transport media name: hydrochloride, hydrogen chlorate, sodium hydroxide,
acrylic (media density are for 1190 kilograms/cubic metres),
acetic acid, glacial acetic acid, hydrogen peroxide (media density are for 1140 kilograms/cubic metres)
Propionic acid, (density for 1110 kilograms/cubic metres),
ammonia, (NH3·H2Odensity for 1090 kilograms/cubic metres),
Hydrochloric acid tank
HINO Chassis optional
Product Categories | HINO chassis | 700 chassis | |
Product Type | FS2PMUM-TQZ | FS2PMUM-SQZ | FY2PUUM-MQZ |
Configuration coding | W1-NR00 | W1-BL00 | W1-DL00 |
Drive mode | 6x4 | 8x4 | |
Maximum gross weight (kg) | 25,000 | 25,000 | 31000 |
Cab | Standard | Standard | Standard |
Dimensions (Length x width x height) (mm) | 8050x2495x3070 | 8050x2495x3070 | 9380x2495x3130 |
Wheelbase (mm) | 3640 + 1410 | 3640 + 1410 | 1850 + 3400 + 1410 |
Front / rear track (mm) | 2060/1855/1855 | 2060/1855/1855 | 2060/2060/1855/1855 |
Front / rear overhang (mm) | 1410/1590 | 1410/1591 | 1410/1310 |
Minimum ground clearance (mm) | ≥220 | ≥220 | ≥240 |
Minimum turning diameter (m) | ≤18.4 | ≤18.4 | ≤20 |
Curb weight (kg) | 9200,9400 | 9200,9400 | 11000 |
Engine Model | P11C-VK | P11C-VK | P11C-VK |
Rated Power (PS) kW / r / min | (350) 259/1900 | (350) 259/1900 | (350) 259/1900 |
Maximum torque Nm / r / min | 1483/1100 | 1483/1100 | 1483/1100 |
Post-processing system | SCR | ||
Displacement L | 10.520 | 10.520 | 10.520 |
Clutch | Dry-type single DSF-430 | Dry-type single DSF-430 | Dry-type single DSF-430 |
Transmission | 12JSD160TA | RT-11509C | 12JSD160TA |
Front / rear axle | THD17 | THD17 | THD18 |
Rear axle Save Ratio | 4.625 | 4.625 | 5.285 |
Tire | 11.00R20 | 11.00R20 | 11.00R20 |
Emission standards | State IV | State IV | State IV |
Our water tank truck with different chassis, eg:DFAC, DFL, SINOTRUCK, CNHTC,NORTH BENS, FOTON, ISUZU, JAC, JMC, KAMA, YUEJIN, etc.
Rotationally Molded LLDPE TANK
chemical resistance of LLDPE Cell / :+8615271357675
www.truckinchina.com
The chemical compatibility of LDPE and HDPE on this chart is tested at 20°C: and 50°C: for 7 days and 30 days (if applicable) with constant exposure.
LDPE & HDPE resistance listed by chemical | |
1.4-dioxane | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE at 50°C: shows some effect after 7 days. |
Acetaldehyde | LDPE / HDPE at 20°C: little or no damage after 30 days. HDPE at 50°C: shows some effect after 7 days. LDPE at 50°C: immediate damage may occur. |
Acetic Acid 5 % | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Acetic Acid, glacial 50% | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE at 50 °C: immediate damage may occur. |
Acetone | LDPE / HDPE at 20°C-50°C: damage may occur. Not recommended for continuous use. |
Allyl Alcohol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Aluminum salts | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Amino acids | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ammonia | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ammonium carbonate saturated | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ammonium phosphate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ammonium sulphate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Amyl chloride | HDPE at 20°C: shows some effect after 7 days. HDPE at 50°C & LDPE at 20°C-50°C: immediate damage may occur. Not recommended for continuous use. |
Aniline | LDPE / HDPE at 20°C: little or no damage after 30 days. HDPE at 50°C: shows some effect after 7 days. |
Benzene | LDPE / HDPE at 20°C-50°C: damage may occur. Not recommended for continuous use. |
Benzyl alcohol | LDPE / HDPE at 50°C: immediate damage may occur. HDPE at 20°C: shows some effect after 7 days. |
Boric acid | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Bromine | LDPE / HDPE at 50°C: immediate damage may occur. HDPE at 20°C: shows some effect after 7 days. |
Butyric acid | LDPE / HDPE at 50°C: immediate damage may occur. HDPE at 20°C: shows some effect after 7 days. |
Calcium chloride | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Calcium hydroxide saturated | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Carbon tetrachloride | HDPE at 20°C: shows little or no damage after 30 days. LDPE at 20°C & HDPE at 50°C: show some effect after 7 days. LDPE at 50°C: not recommended. |
Chlorine 10% in water | LDPE / HDPE at 20°C: shows little or no damage after 30 days. LDPE at 50°C: shows damage and is not recommended. |
Chlorobenzene | Immediate damage may occur. Not recommended for continuous use. |
Chloroform | LDPE / HDPE at 20°C: show some effect after 7 days. LDPE / HDPE at 50°C: immediate damage may occur. Not recommended for continuous use. |
Chromic acid 10% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Chromic acid 50% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Citric acid 10% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Cresol | HDPE at 20°C: shows some effect after 7 days. LDPE at 20°C-50°C & HDPE at 50°C: show immediate damage. Not recommended for continuous use. |
Cyclohexane | LDPE / HDPE at 50°C: immediate damage may occur. LDPE / HDPE at 20°C: show some effect after 7 days. |
Diethyl ketone | LDPE / HDPE at 20°C-50°C: damage may occur. Not recommended for continuous use. |
Dimethylsulfoxide | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ethanol 95% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ethyl acetate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ethyl benzene | HDPE at 20°C: shows some effect after 7 days. LDPE at 20°C-50°C & HDPE at 50°C: show immediate damage. Not recommended for continuous use. |
Ethylene glycol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ethylene oxide | HDPE at 20°C: shows little or no damage after 30 days. LDPE at 20°C: and LDPE/ HDPE at 50°C: show some effect after 7 days. |
Ferric chloride | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Fluoride | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Fluorine | HDPE at 20°C: shows little or no damage after 30 days. LDPE at 20°C: shows some effect after 7 days. Not recommended at 50°C. |
Formaldehyde 10% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Formaldehyde 40% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Glycerol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hexane | HDPE at 20°C: shows little or no damage after 30 days continuous use. HDPE at 50 °C: shows some effect after 7 days. LDPE not recommended at any temperature. |
Hydrochloric acid 20% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrochloric acid 35% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrochloric acid 5% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrocyanic acid | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrofluoric acid | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrofluoric acid 4% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrofluoric acid 48% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrogen peroxide 3% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrogen peroxide 30% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Isobutyl alcohol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Isopropyl alcohol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Kerosene | LDPE / HDPE at 20°C: show some effect after 7 days. LDPE / HDPE not recommended at 50°C, as immediate damage may occur. |
Lactic Acid 10 % | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Lactic Acid 90 % | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Lead acetate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Methanol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Methyl ethyl ketone | Immediate damage may occur. Not recommended for continuous use. |
Methyl propyl ketone | HDPE at 20°C: shows some effect after 7 days. LDPE at 20°C-50°C & HDPE at 50°C: Immediate damage may occur. Not recommended for continuous use. |
Methylene chloride | HDPE at 20°C: shows some effect after 7 days. LDPE at 20°C-50°C & HDPE at 50°C: Immediate damage may occur. Not recommended for continuous use. |
Mineral oil | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE at 50°C: may show immediate damage and is not recommended. |
n-amyl acetate | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE at 50°C: shows some effect after 7 days or constant exposure. |
n-butyl alcohol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Nitric acid 50 % | LDPE at 20°C: shows little or damage after 30 days. HDPE at 20°C & LDPE at 50°C: show effect after 7 days. HDPE at 50°C: shows immediate damage and is not recommended. |
Nitric acid 70 % | LDPE / HDPE at 20°C: show some effect after 7 days. LDPE / HDPE at 50°C: show immediate damage. Not recommended. |
n-octane | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Oleic acid | HDPE at 20°C-50°C: little or no damage after 30 days. LDPE at 20°C-50°C: shows immediate damage and is not recommended. |
Oxalic acid | LDPE at 20°C: shows some effect after 7 days. HDPE at 20°C and LDPE / HDPE at 50°C: shows little/ no damage after 30 days. |
Ozone | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE / HDPE at 50°C: show immediate damage. Not recommended. |
Perchloric acid | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE / HDPE at 50°C: show immediate damage. Not recommended. |
Perchloric ethylene | LDPE / HDPE at 20°C-50°C: show immediate damage. Not recommended. |
Phenol | LDPE / HDPE at 20°C-50°C: show immediate damage. Not recommended. |
Phosphoric acid 10% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Phosphoric acid 85% | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE at 50°C: shows immediate damage and is not recommended. |
Phosphorous trichloride | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE at 50°C: has no data available. HDPE at 50°C: shows some effect after 7 days. |
Potassium carbonate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Potassium hydroxide 5 % | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Potassium hydroxide concentrated | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Potassium permanganate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Propylene glycol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Pyridine | Immediate damage may occur. Not recommended for continuous use. |
Salicylic acid, saturated | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Silver acetate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Silver nitrate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sodium carbonate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sodium chloride, saturated | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sodium dichromate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sodium hydroxide 1% | LDPE at 20°C-50°C: shows little or no damage after 30 days. HDPE at 20°C-50°C: shows some effect after 7 days. |
Sodium hydroxide 50% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sodium hypochlorite 15% | HDPE at 20°C-50°C: little or no damage after 30 days. LDPE at 20°C: is suitable but at 50°C: shows some effect after 7 days. |
Sodium nitrate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sodium sulphate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sucrose | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sulfuric acid 20% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sulfuric acid 6% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sulfuric acid 60% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sulfuric acid 98% | LDPE at 20°C-50°C: shows little or no damage after 30 days. HDPE at 20°C: shows effect after 7 days. Not recommended for use at 50°C. |
Tannic acid | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Tetrahydrofuran | LDPE / HDPE at 20°C: show some effect after 7 day of constant exposure. LDPE / HDPE at 50°C: show immediate damage. Not recommended. |
Toluene | LDPE at 20°C: show some effect after 7 day of constant exposure. HDPE at 20°C-50°C & LDPE at 50°C: show immediate damage. Not recommended. |
Trichloracetic acid | LDPE / HDPE at 20°C: show some effect after 7 day of constant exposure. LDPE / HDPE at 50°C: show immediate damage. Not recommended. |
Trichlorethane | Immediate damage may occur. Not recommended for continuous use. |
Turpentine oil | LDPE / HDPE at 20°C: show some effect after 7 days. LDPE / HDPE at 50°C: show immediate damage. Not recommended. |
Urea | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Xylene | HDPE at 20°C: shows some effect after 7 day of constant exposure. LDPE at 20-50°C and HDPE at 50°C: show immediate damage. Not recommended. |
Zinc chloride | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hino 700 6X4 Tanker Truck 350HP 15000~16000L ( For Chemical Acid Liquid ,Drink Water,Oil , Carbon Steel / Stainless Steel ,Lined PE Tank)
HINO 700 18cbm road tanker truck 350HP
15000 ~16000Litres
HINO 700Acid oil tanker truck for HCL, NaCIO acid Tank hydrochloric acid -HCL, dilute sulphuric acid WEAK SULFURIC ACID -H2SO4 ,sodium hypochlorite - NaCIO ,Caustic soda-NaOH
Customization, Cost and Control Built How You Want it, at a Price You Can Afford. for sale 86-152 -7135-7675 Steel Lined LDPE aslo for HCL(max 35%), NaOH (max 50%), NaCLO (max 10%), PAC (max 17%),H2SO4(60%,98%) ,HF ( 48%),H3PO4 (10%-85%),NH3. H2O,H2O2 (30%)
# | Engine model | Engine displacement | Engine power | Engine manufacturer | |||
1 | P11C-WB | 10520 cc | 10.5 L | 642 cuin | 240 kW | 327 hp | Shanghai Hino Engine Co., Ltd. |
Performance | ||
Fuel | diesel fuel | |
Maximum speed | 80 km/h | 50 mph |
ABS | have |
Weights and Ground pressure | |||
Curb weight | 14500 kg | 14.5 | |
Gross vehicle weight rating | 25000 kg | 25 t | 55,000 lbs |
Axle load distribution | 7000 kg / 18000 kg (tandem axle) 7 t / 18 t (tandem axle) 15,000 lbs / 40,000 lbs (tandem axle) |
Dimensions 9.42×2.5×3.97 | ||
Overall length | 9420 mm | |
Overall width | 2490 mm | |
Overall height | 3970 mm |
Undercarriage and Suspension | ||
Number of axles | 3 | |
Wheelbase | 3350+1410 mm | |
Front track | 2060 mm | 6′10″ |
Rear track | 1855 mm / 1855 mm | 6′2″ / 6′2″ |
Front overhang | 1460 mm | 4′10″ |
Rear overhang | 1290 mm | 4′3″ |
Angle of approach | 27° | |
Angle of departure | 39° | |
Leaf springs | 11/13,10/13 |
Tyres and Wheels | |
Number of tyres | 10 |
Tyres dimension | 11R22.5 |
Miscellaneous | |
Seating capacity | 2 |
Steering control | steering wheel |
transport media name: hydrochloride, hydrogen chlorate, sodium hydroxide,
acrylic (media density are for 1190 kilograms/cubic metres),
acetic acid, glacial acetic acid, hydrogen peroxide (media density are for 1140 kilograms/cubic metres)
Propionic acid, (density for 1110 kilograms/cubic metres),
ammonia, (NH3·H2Odensity for 1090 kilograms/cubic metres),
Hydrochloric acid tank
HINO Chassis optional
Product Categories | HINO chassis | 700 chassis | |
Product Type | FS2PMUM-TQZ | FS2PMUM-SQZ | FY2PUUM-MQZ |
Configuration coding | W1-NR00 | W1-BL00 | W1-DL00 |
Drive mode | 6x4 | 8x4 | |
Maximum gross weight (kg) | 25,000 | 25,000 | 31000 |
Cab | Standard | Standard | Standard |
Dimensions (Length x width x height) (mm) | 8050x2495x3070 | 8050x2495x3070 | 9380x2495x3130 |
Wheelbase (mm) | 3640 + 1410 | 3640 + 1410 | 1850 + 3400 + 1410 |
Front / rear track (mm) | 2060/1855/1855 | 2060/1855/1855 | 2060/2060/1855/1855 |
Front / rear overhang (mm) | 1410/1590 | 1410/1591 | 1410/1310 |
Minimum ground clearance (mm) | ≥220 | ≥220 | ≥240 |
Minimum turning diameter (m) | ≤18.4 | ≤18.4 | ≤20 |
Curb weight (kg) | 9200,9400 | 9200,9400 | 11000 |
Engine Model | P11C-VK | P11C-VK | P11C-VK |
Rated Power (PS) kW / r / min | (350) 259/1900 | (350) 259/1900 | (350) 259/1900 |
Maximum torque Nm / r / min | 1483/1100 | 1483/1100 | 1483/1100 |
Post-processing system | SCR | ||
Displacement L | 10.520 | 10.520 | 10.520 |
Clutch | Dry-type single DSF-430 | Dry-type single DSF-430 | Dry-type single DSF-430 |
Transmission | 12JSD160TA | RT-11509C | 12JSD160TA |
Front / rear axle | THD17 | THD17 | THD18 |
Rear axle Save Ratio | 4.625 | 4.625 | 5.285 |
Tire | 11.00R20 | 11.00R20 | 11.00R20 |
Emission standards | State IV | State IV | State IV |
Our water tank truck with different chassis, eg:DFAC, DFL, SINOTRUCK, CNHTC,NORTH BENS, FOTON, ISUZU, JAC, JMC, KAMA, YUEJIN, etc.
Rotationally Molded LLDPE TANK
chemical resistance of LLDPE Cell / :+8615271357675
www.truckinchina.com
The chemical compatibility of LDPE and HDPE on this chart is tested at 20°C: and 50°C: for 7 days and 30 days (if applicable) with constant exposure.
LDPE & HDPE resistance listed by chemical | |
1.4-dioxane | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE at 50°C: shows some effect after 7 days. |
Acetaldehyde | LDPE / HDPE at 20°C: little or no damage after 30 days. HDPE at 50°C: shows some effect after 7 days. LDPE at 50°C: immediate damage may occur. |
Acetic Acid 5 % | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Acetic Acid, glacial 50% | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE at 50 °C: immediate damage may occur. |
Acetone | LDPE / HDPE at 20°C-50°C: damage may occur. Not recommended for continuous use. |
Allyl Alcohol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Aluminum salts | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Amino acids | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ammonia | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ammonium carbonate saturated | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ammonium phosphate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ammonium sulphate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Amyl chloride | HDPE at 20°C: shows some effect after 7 days. HDPE at 50°C & LDPE at 20°C-50°C: immediate damage may occur. Not recommended for continuous use. |
Aniline | LDPE / HDPE at 20°C: little or no damage after 30 days. HDPE at 50°C: shows some effect after 7 days. |
Benzene | LDPE / HDPE at 20°C-50°C: damage may occur. Not recommended for continuous use. |
Benzyl alcohol | LDPE / HDPE at 50°C: immediate damage may occur. HDPE at 20°C: shows some effect after 7 days. |
Boric acid | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Bromine | LDPE / HDPE at 50°C: immediate damage may occur. HDPE at 20°C: shows some effect after 7 days. |
Butyric acid | LDPE / HDPE at 50°C: immediate damage may occur. HDPE at 20°C: shows some effect after 7 days. |
Calcium chloride | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Calcium hydroxide saturated | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Carbon tetrachloride | HDPE at 20°C: shows little or no damage after 30 days. LDPE at 20°C & HDPE at 50°C: show some effect after 7 days. LDPE at 50°C: not recommended. |
Chlorine 10% in water | LDPE / HDPE at 20°C: shows little or no damage after 30 days. LDPE at 50°C: shows damage and is not recommended. |
Chlorobenzene | Immediate damage may occur. Not recommended for continuous use. |
Chloroform | LDPE / HDPE at 20°C: show some effect after 7 days. LDPE / HDPE at 50°C: immediate damage may occur. Not recommended for continuous use. |
Chromic acid 10% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Chromic acid 50% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Citric acid 10% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Cresol | HDPE at 20°C: shows some effect after 7 days. LDPE at 20°C-50°C & HDPE at 50°C: show immediate damage. Not recommended for continuous use. |
Cyclohexane | LDPE / HDPE at 50°C: immediate damage may occur. LDPE / HDPE at 20°C: show some effect after 7 days. |
Diethyl ketone | LDPE / HDPE at 20°C-50°C: damage may occur. Not recommended for continuous use. |
Dimethylsulfoxide | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ethanol 95% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ethyl acetate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ethyl benzene | HDPE at 20°C: shows some effect after 7 days. LDPE at 20°C-50°C & HDPE at 50°C: show immediate damage. Not recommended for continuous use. |
Ethylene glycol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ethylene oxide | HDPE at 20°C: shows little or no damage after 30 days. LDPE at 20°C: and LDPE/ HDPE at 50°C: show some effect after 7 days. |
Ferric chloride | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Fluoride | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Fluorine | HDPE at 20°C: shows little or no damage after 30 days. LDPE at 20°C: shows some effect after 7 days. Not recommended at 50°C. |
Formaldehyde 10% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Formaldehyde 40% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Glycerol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hexane | HDPE at 20°C: shows little or no damage after 30 days continuous use. HDPE at 50 °C: shows some effect after 7 days. LDPE not recommended at any temperature. |
Hydrochloric acid 20% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrochloric acid 35% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrochloric acid 5% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrocyanic acid | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrofluoric acid | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrofluoric acid 4% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrofluoric acid 48% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrogen peroxide 3% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrogen peroxide 30% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Isobutyl alcohol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Isopropyl alcohol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Kerosene | LDPE / HDPE at 20°C: show some effect after 7 days. LDPE / HDPE not recommended at 50°C, as immediate damage may occur. |
Lactic Acid 10 % | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Lactic Acid 90 % | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Lead acetate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Methanol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Methyl ethyl ketone | Immediate damage may occur. Not recommended for continuous use. |
Methyl propyl ketone | HDPE at 20°C: shows some effect after 7 days. LDPE at 20°C-50°C & HDPE at 50°C: Immediate damage may occur. Not recommended for continuous use. |
Methylene chloride | HDPE at 20°C: shows some effect after 7 days. LDPE at 20°C-50°C & HDPE at 50°C: Immediate damage may occur. Not recommended for continuous use. |
Mineral oil | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE at 50°C: may show immediate damage and is not recommended. |
n-amyl acetate | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE at 50°C: shows some effect after 7 days or constant exposure. |
n-butyl alcohol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Nitric acid 50 % | LDPE at 20°C: shows little or damage after 30 days. HDPE at 20°C & LDPE at 50°C: show effect after 7 days. HDPE at 50°C: shows immediate damage and is not recommended. |
Nitric acid 70 % | LDPE / HDPE at 20°C: show some effect after 7 days. LDPE / HDPE at 50°C: show immediate damage. Not recommended. |
n-octane | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Oleic acid | HDPE at 20°C-50°C: little or no damage after 30 days. LDPE at 20°C-50°C: shows immediate damage and is not recommended. |
Oxalic acid | LDPE at 20°C: shows some effect after 7 days. HDPE at 20°C and LDPE / HDPE at 50°C: shows little/ no damage after 30 days. |
Ozone | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE / HDPE at 50°C: show immediate damage. Not recommended. |
Perchloric acid | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE / HDPE at 50°C: show immediate damage. Not recommended. |
Perchloric ethylene | LDPE / HDPE at 20°C-50°C: show immediate damage. Not recommended. |
Phenol | LDPE / HDPE at 20°C-50°C: show immediate damage. Not recommended. |
Phosphoric acid 10% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Phosphoric acid 85% | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE at 50°C: shows immediate damage and is not recommended. |
Phosphorous trichloride | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE at 50°C: has no data available. HDPE at 50°C: shows some effect after 7 days. |
Potassium carbonate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Potassium hydroxide 5 % | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Potassium hydroxide concentrated | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Potassium permanganate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Propylene glycol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Pyridine | Immediate damage may occur. Not recommended for continuous use. |
Salicylic acid, saturated | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Silver acetate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Silver nitrate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sodium carbonate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sodium chloride, saturated | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sodium dichromate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sodium hydroxide 1% | LDPE at 20°C-50°C: shows little or no damage after 30 days. HDPE at 20°C-50°C: shows some effect after 7 days. |
Sodium hydroxide 50% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sodium hypochlorite 15% | HDPE at 20°C-50°C: little or no damage after 30 days. LDPE at 20°C: is suitable but at 50°C: shows some effect after 7 days. |
Sodium nitrate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sodium sulphate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sucrose | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sulfuric acid 20% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sulfuric acid 6% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sulfuric acid 60% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sulfuric acid 98% | LDPE at 20°C-50°C: shows little or no damage after 30 days. HDPE at 20°C: shows effect after 7 days. Not recommended for use at 50°C. |
Tannic acid | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Tetrahydrofuran | LDPE / HDPE at 20°C: show some effect after 7 day of constant exposure. LDPE / HDPE at 50°C: show immediate damage. Not recommended. |
Toluene | LDPE at 20°C: show some effect after 7 day of constant exposure. HDPE at 20°C-50°C & LDPE at 50°C: show immediate damage. Not recommended. |
Trichloracetic acid | LDPE / HDPE at 20°C: show some effect after 7 day of constant exposure. LDPE / HDPE at 50°C: show immediate damage. Not recommended. |
Trichlorethane | Immediate damage may occur. Not recommended for continuous use. |
Turpentine oil | LDPE / HDPE at 20°C: show some effect after 7 days. LDPE / HDPE at 50°C: show immediate damage. Not recommended. |
Urea | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Xylene | HDPE at 20°C: shows some effect after 7 day of constant exposure. LDPE at 20-50°C and HDPE at 50°C: show immediate damage. Not recommended. |
Zinc chloride | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
3 Sets Lined PE Tanks 6604Gallon For Storage Transport Sodium Hypochlorite to Saudi Arabia FROM WUHAN PORT CHINA TO DAMMAM, SAUDI ARABIA BY SEA. + Port of loading : WUHAN PORT + Port of unloading :DAMMAM CAST IRON STORAGE TANK FOR CHEMICAL MATERIALS STORAGE TANK CAPACITY: 25M3 HS CODE:730900 10.2x2.1x2.5*3 160.65cbm 3X40HQ
4PCS Power Take-off PTO FOR JMC TRANSMISSION MODEL DN3-7003-EC 6MT1420 to URUGUAY Sdq51/65 (Gearbox Power Take off For ISUZU QINGLING Transmission DN3-70030-E0, 6MT1420 PTO Assembly) HWP-G32/65CHQ ,32/65 PQ1
12PCS PTO Wanliyang Transmission Power Take-off For WLY6T40 WLY6TS40 to Mexico 1 PC SDQ211/60LGQ1 PTO FOR 6DS60T-D TO SAUDI ARABIA
6 units Metal Alky C480 Portable Tank TEAL DEAC Cylinder for Singapore 360 DEG. ROTATABLE TOP FLANGE VALVE (KV-MTFF DN15 PN 40), 360 DEG. ROTATABLE TOP FLANGE VALVE (KV-MTFE DN20 PN 40) K4430 Gaskets
2 Units Righ Hand Drive Shacman F3000 Hydro Excavators Truck Combined Vacuum Sewer Jetting to Suva Port Fiji Shacman F3000 Hydro Excavators Truck Sewer Jet Suction Units (RHD 13500L Sewage+4000L Clean Water ) PTO, transmission shaft, vacuum pump, tanker, hydraulic system and jetting pipe system. Combined Sewer Suction & Jetting Unit SZW Aluminium Alloy Liquid Water Ring Compressor Vacuum Pump XW-2800 VAC Flow 2800 M³/h ,1648 Cfm 46.7M3/min 75KW
6 Sets Lined PE Tanks 6604Gallon For Storage Transport Hydrochloric Acid (HCl) to Saudi Arabia FROM WUHAN PORT CHINA TO DAMMAM, SAUDI ARABIA BY SEA. Port of loading : WUHAN PORT + Port of unloading :DAMMAM DONG RUN ZE CAST IRON STORAGE TANK FOR CHEMICAL MATERIALS STORAGE TANK CAPACITY: 25M3 HS CODE:7309000000 9.7x2.2x2.5*6
80Units Metal Alky C480 UN Portable Tank T21 TEAL Cylinders to USA 80Units UN T21 Portable Tank Container 1880L Cylinder For TEAL Metal Alkyls UN3394 UN3399 to USA Adr/Rid Organometallic Substance, Liquid, Water- Reactive C-430 Saddle Type Portable Tank , tank capacity 1630L C-480 Saddle Type Portable Tank, tank capacity 1880L C-1980 TEAL TMGa ,TEGa,TMIn, TMAl DEAC Metal Alky C-1980 T21 Metal Alky 7495L
2 Sets Hydrochloric Acid HCL Tank Container Lined PE 24m3 Trailer Mounted to Vietnam
10 Units 22KL 20FT ISO Steel Lined PE Hydrochloric Acid HCL Tank Container to Vietnam 20FT Tank Container PE Lined Tank Used to contain: HCl (max 35%), NaOH (max 50%), PAC (max 17%),H2SO4(max 94%) etc… Tank Capacity: 21,000 Liters Steel sheet 6mm, head 6mm Liner thickness: 16mm PE 01pc butterfly valve CS/F46 and 01pc ball valve CS/F46 DRAU2209015 DRAU2209020 DRAU2209036 DRAU2209041 DRAU2209057 DRAU2209062 DRAU2209078 DRAU2209083 DRAU2209099 DRAU2209102
2 Sets Hydrochloric Acid Hydrofluoric Acid Road transport 20Ft Tank Container to Chennai India DTAU2200916 DTAU2200921
20Ft Nitric Acid (Hno3)Tank Container Pure 1060 Aluminum Tank DAF Huu Nghi ALUMINUM TANK FOR NITRIC ACID (HNO3 98%) ROAD TRANSPORT TANK THICKNESS 12MM CAPACITY18,000LITRES TANK SIZE Φ2000×5500 TANK SHELL MATERIAL AAA ALUMINUM / 12.00 MM HEAD PLATE MATERIAL AAA ALUMINUM / 14.00 MM WAVE PLATE AAA ALUMINUM / 8.00 MM CONTAINER FRAME 6058×2438×2591 LOCK BASE STEEL CASTING 45 #(180×165×120) CONTAINER COLUMN SQUARE TUBE Q235 / 4.00MM(120×120×4) CONTAINER CROSS FRAME SQUARE TUBE Q235 / 4.00MM(120×100×4) DATE OF MANUFACTURER 2022-09-06 MANHOLE COVER 316L STAINLESS STEEL,DN500, 0.4MPA, -40C~150C, MADE 2022-06 DISCHARGE VALVE Q41F-16C4/DN65,1.6MPA,<80C. MADE 2022-04 BUTTERFLY VALVE D71F-16RL,1.6MPA, MADE 2022-09 BREATHER VALVE 316L STAINLESS STEEL HXF-50,-20C~150C, MADE 2022-04
3 Sets Hydrochloric Acid HCL Tanker Lined PE Tank body for Cargo Truck 13m3 -16.5m3 to Vietnam TWO (2) UNITS OF TANK FOR HCL CARGO TRUCK 3 COMPARTMENTS TANK CAPACITY:16500 LITERS HS CODE: 7309.00 ONE (1) UNITS OF TANK FOR HCL CARGO TRUCK3 COMPARTMENTS TANK CAPACITY:13000LITERS HS CODE: 7309.00 THIRTY (30) UNITS OF LID WITH FLANGE #37CMTHREAD CAP PE LID VORTEX SCREW STRUCTURE HS CODE: 3923.50 PACKING: TOTAL 9 PACKAGES(3 NUDE PACKAGES +6BOXES) ONLY
20Sets Power take-offs (PTOs) WLY5G32 ,6DS60T-D ,8JS85 ,DC7J120T to Ecuador C&F GUAYAQUIL, EC LCL. CFS-CFS Part No. Description Quantity SDQ 24/63-B LGQ1 PTO For WLY5G32 5.595 7 SDQ34/29LGQ1 " PTO FOR 8JS85E GEAR SPLINE" 3 SDQ34/29PQ1 " PTO FOR 8JS85E GEAR FLANGE" 2 SDQ211-60LGQ1 "PTO FOR 6DS60T-D GEAR SPLINE" 3 SDQ211-60PQ1 "PTO FOR 6DS60T-D GEAR SPLINE" 2 DC7J120T "PTO for DC7J120T (DC7J120TC )1a10.307" 3
6000Liters Lined PE Mobile Hydrochloric Acid (HCl) Tank For Truck Lorry Ready for Export STEEL SHELL 5MM, HEAD 6MM TANK SIZE :3800*1900*1230MM, OVER ALL SIZE3800*1900*1800MM DISCHARGE VALVE ND80/DN 65
32Units UN T21 Portable Tank Container 1880L Cylinder For TEAL Metal Alkyls UN3394 UN3399 to USA Adr/Rid Organometallic Substance, Liquid, Water- Reactive C-430 Saddle Type Portable Tank , tank capacity 1630L C-480 Saddle Type Portable Tank, tank capacity 1880L C-1980 TEAL TMGa ,TEGa,TMIn, TMAl DEAC Metal Alky C-1980 T21 Metal Alky 7495L What more there are another 80 units UN T21 Portable Tanks PO on our producing Line,hoping be ready for delivery on 2022.10.10.