Reefer dolly Trailer Customizing
Trailer view
Product Description
Reefer dolly Trailer Customizing
truck cooling units for fresh food Specification:
Model | Refrigerant | Cooling capacity*(Road) | Blowing rate | Condenser | Evaporator | Apply for | |||
0℃/+30℃ | -18/+30℃ | m³/h | Dimension(mm) | Weight(kg) | Dimension(mm) | Weight(kg) | (m³) | ||
KX-550B | R404a | 5800 | 3000 | 2200 | 1456x540x505 | 60 | 1224x508x278 | 32 | 20~30 |
KX-760B | R404a | 7225 | 3860 | 2460 | 1456x540x505 | 62 | 1224x555x278 | 36 | 35~45 |
KX-860B | R404a | 7850 | 4865 | 2650 | 1456x540x505 | 63 | 1227x652x303 | 41 | 40~50 |
KX-960B | R404a | 8425 | 5365 | 2860 | 1456x540x505 | 66 | 1227x652x328 | 43 | 50~60 |
transport refrigeration units Specification:
del | Refrigerant | Cooling capactity*(W) | Blowing rate | Condenser | Evaporator | Apply for | |||
0℃/+30℃ | -18/+30℃ | m³/h | Dimension(mm) | Weight(kg) | Dimension(mm) | Weight(kg) | (m³) | ||
KX-450 | R404a | 4100 | 2600 | 1800 | 1020x435x315 | 32 | 1105x649x230 | 17 | 18~25 |
KX-650 | R404a | 5800 | 3000 | 2400 | 1150x570x430 | 60 | 1530x649x230 | 38 | 25~35 |
Key feature:
1. Streamlined appearance. beautiful and elegant |
2. Internal ultra-thin evaporator. greatly increase the cargo capacity of the container. |
3. Large refrigerating capacity of the unit to ensure the safety of the transport of goods. Even in case of high temperature and to open the doors too often. the unit still can maintain good performance. |
4. Big air volume. maintain fresh quality of the goods. |
5. Wide range of temperature control(-30°C to +30°C). |
6. Computer control. easy operation. safety. |
7. Fast installation. convenient maintenance. saving operating costs. |
8. Meet the requirements of environmental safety. |
9. Show the inside temperature. |
10. Voltage display. high and low voltage alarm. |
11. Optional data recorder. heating and power function. |
Refrigeration units standard configuration:
1. HFC R404a Environmental protection refrigerants. |
2. Multi-function operating panel. |
3. Ultra-thin evaporator. |
4. Hot gas defrosting system. |
5. 12V or 24V operating voltage. |
6. There’s liquid cooling when environmental temperature is too high. to insure compressor. |
Safety guard:
1. Emergency switch protection. |
2. Thermal protection guard. |
3. Refrigeration system high. low voltage protection. |
4. Safe installation instruction. can improve the protective of electromagnetic interference. |
Operating and control component:
1. Micro computer control system. |
2. Automatic/ Manual defrost. |
3. Digital display. |
4. Fahrenheit or Celsius display set point temperature and return air temperature. |
5. Data set parameters and alarm |