T22 T21 T20 Stainless Steel Portable Tanks High Pressure High Purity Ultrapure Industrial Gas Cylinder 8L,19L,40L,80L,106L,110L,450L 516L
Product Description
T22 T21 T20 Stainless Steel Portable Tanks
SiH2CI2 SiHCI3 CIF3 HF WF3 BCI3………
High Pressure High Purity Ultrapure Industrial Gas Cylinder 8L,19L,40L,80L,106L,110L,450L 516L
TS、UN、IMDG、TPED、DOT (CCS、BV)
T22 T21 T20 Portable Tanks are constructed using high-quality stainless steel (316L or 316Ti) and come equipped with a 10mm shell thickness.
T22 mobile containers are suitable for the transportation of dangerous goods as categorized in classes 4.2, 5.1, 6.1, and 8. by road, rail, and sea.
They are purpose-designed to meet most international requirements for transportation, including:
IMDG/ADR , ASME Ⅷ Div.1
US DOT CFR49
Customs Convention - TIR
ISO standards ISO 18172-1 IMDG Coed QYCDT001-2021 GB/T 32566
VOLUME :450 - 2500 Liters
Price for refer
only. Final Price Offer Discount.
Stainless Steel Portable Tanks
VOLUME | DIAMETER | HEIGHT | WEIGHT | BASE DIMENSION |
450 L | 1100 mm | Ca. 1100 mm | Ca. 700 Kg | 1125x1125 mm |
1100 L | 1100 mm | Ca. 1800 mm | Ca. 800 Kg | 1125x1125 mm |
2500 L | 1100 mm | Ca. 2100 mm | Ca. 1200 Kg | 1640x1640 mm |
PRODUCT DESCRIPTION
Stainless steel 316L or 316Ti
Test pressure: 15 bar
Maximum allowable working pressure: 10 bar
Full vacuum
Design temperature: -40ºC to 65ºC
Base frame constructed of carbon steel
Four lifting lugs
Ladder: optional, located at rear
Walkway: optional
PRODUCT APPLICATIONS
High Purity Poison Gas Tank Cylinder With UN,IMDG,TPED,DOT
Maximum service pressure 2.2/-0.103MPa @ 65 ℃
Pressure test pressure 3.3MPa
Helium leak detection rate ≤ 1X10-9 pa. m ⊃3;/ s
Water oxygen content is dry and nitrogen seal is delivered (without valve and copper plug)
Polishing grade EP, Ra ≤ 0.07-0.25 um
Valve type: manual and pneumatic right-angle diaphragm valve
Valve interface type 1, DISS636/CGA636 (Outlet connection)
2、3/4-14NGT /W28 14T.P.I(Inter connection)
Adapted valve Rotarex Kohda Neriki Ermeto
Ultrapure Industrial Gas Metal Alkyls Tank Cylinder 8L,~516L
Dichlorosilane - ( SiH2CL2 ,DCS ) | ||||
Description | ||||
Dichlorosilane is a highly toxic , colorless , flammable and liquefied gas with a sharp , pungent odor . It hydrolyses on contact with water to form | ||||
Specifications | ||||
Purity , % | 99 | 99.9 | ||
Typical Resistivity | ≥ 200 ohm-cm | ≥ 400 ohm-cm | ||
Monochlorosilane | ≤ 0.2% | ≤ 100 pm | ||
Trichlorosilane | ≤ 0.5% | ≤ 200 pm | ||
Silicon Tetrachloride | ≤ 0.1% | ≤ 100 pm | ||
Other Chlorosilanes | ≤ 1 wt % | ≤ 500 pm | ||
Ship | ||||
DOT Shipping Name | Poison Inhalation Hazard | |||
DOT Classification | 2.3 | |||
DOT Label | Poison Gas, Nonflammable Gas | |||
UN Number | UN 2189 | |||
CAS No. | 4109-96-0 | |||
CGA/DISS/JIS | 678/636/W22-14L | |||
Shipped as | Liquefied Gas | |||
Technical Information | ||||
Cylinder State @ 21.1°C | Liquid | |||
Flammable Limits In Air | 4.1-98.8% | |||
Auto Ignition Temperature (°C ) | 100 | |||
Molecular Weight (g/mol) | 101.01 | |||
Specific gravity (air =1) | 3.47 | |||
Critical Temperature ( °C ) | 175.85 | |||
Critical Pressure ( psig ) | 678.2 | |||
Applications | ||||
· SiH2CL2 is silicon precursor gas used in combination with ammonia for silicon nitride chemical vapor deposition ( CVD ). | ||||
Molecular Formula | C3H9Al |
Synonyms | Trimethylaluminum UN 3399 ,UN 3394 TRIMETHYLALUMINIUM 75-24-1 Aluminum, trimethyl- Trimethylalane |
Molecular Formula | C6H15Al |
Synonyms | TRIETHYLALUMINUM UN 3399 UN 3394 97-93-8 Triethylaluminium Aluminum, triethyl- triethylalumane |
Molecular Formula | C3H9Ga |
Synonyms | TRIMETHYLGALLIUM 1445-79-0 Gallium, trimethyl- trimethylgallane MFCD00014841 |
Molecular Formula | C6H15Ga |
Synonyms | Triethylgallium Gallium, triethyl- 1115-99-7 triethylgallane Triethyl gallium |
Molecular Formula | C3H9Sb |
Synonyms | Trimethylantimony Trimethylstibine trimethylstibane 594-10-5 STIBINE, TRIMETHYL- |
Molecular Formula | In(CH3)3 or C3H9In |
Synonyms | Trimethylindium 3385-78-2 Indium, trimethyl- trimethylindigane MFCD00014846 |
Molecular Formula | C10H10Fe |
Synonyms | Ferrocene U96PKG90JQ CCRIS 3195 HSDB 2878 EINECS 203-039-3 |
Molecular Formula | C4H10Te |
Synonyms | Diethyltelluride Diethyltellurium 627-54-3 Diethyl telluride TELLURIUM DIETHYL |
Molecular Formula | C2H6Zn |
Synonyms | Dimethylzinc UN 3399 544-97-8 Zinc, dimethyl- DIMETHYL ZINC Methylzinc |
Molecular Formula | C4H10Zn |
Synonyms | Diethylzinc UN 1366 557-20-0 Zinc, diethyl- DIETHYL ZINC Zinc ethide |
Molecular Formula | Cl2H2Si or SiH2Cl2 |
Synonyms | dichlorosilane Dichlorosilane [UN2189] [Poison gas] Dichlorosilane, >=99.99% trace metals basis DTXSID1052082 EINECS 223-888-3 |
Molecular Formula | F6W or WF6 |
Synonyms | Tungsten hexafluoride UN 2196 Hexafluorotungsten 7783-82-6 Tungsten fluoride (WF6), (OC-6-11)- Tungsten(VI) fluoride |
Molecular Formula | BF3 |
Synonyms | BORON TRIFLUORIDE UN 1008 Trifluoroborane Borane, trifluoro- Boron fluoride Trifluoroboron |
Substances susceptible to spontaneous combustion, such as copra, phoshorous (yellow or white) and unstabilized fishmeal
Certain fertilizers such as, ammonium nitrate
Oxidizing agents, including swimming pool treatments (calcium hypochlorite, hydrogen peroxide)
Toxic products such as sodium cyanide used for metal treatment, agricultural insecticides and chromium salts for electroplating processes
Copper chrome arsenate mixtures for timber preservatives
Potassium hydroxide (caustic potash), sodium hydroxide (caustic soda)
Dairy sanitizers and industrial cleaners
Acids including sulphuric, nitric and hydrochloric, which are used for many industrial processes
View more at Youtu.be and follow us.
ISOTANK List
The Main Technical Parameters of Tanks (ASME Standard) | ||||||||||||
| Loading Medium | Model | Capacity | Design | Design | Tank Material | Nominal Tank | Insulation | Tare weight | Max. Gross Weight | Dimension | Loading Method |
1 | R134a | T50 | 24 | 1.38 | -40 /+55 | SA-612N | 11 | Sunshade | 6400 | 34000 | 6058 X 2438 X2591 | Down load unload |
2 | R22 | 22 | 2.1 | -40/+50 | 18 | 8800 | ||||||
3 | R143a | 22 | 2.42 | 20 | 9500 | |||||||
4 | R125 | 22 | 2.75 | 21 | 9500 | |||||||
5 | R32 | 20 | 3.44 | 25 | 10900 | |||||||
6 | AHF | T19 | 21 | 1.0 | -40/+55 | SA516M NGr.485 | 12 | No | 6900 | Up load unload | ||
7 | Trichlorosilan | T14 | 21 | 0.5 | -40/+50 | Q345R | 12 | No | 6780 | 34000 | 6058 X 2438 X2591 | |
8 | Liquid Chlorine | T50 | 20 | 1.7 | -40/+50 | 16 | 8300 | |||||
9 | 21.72 | 1.62 | 16 | 8900 | ||||||||
10 | Liquid | T50 | 21.6 | 2.2 | -40/+50 | 06Cr19Ni10 | 22 | Packing Insulation | 11970 | |||
11 | SO2 | T20 | 21 | 1.03 | 40 /+60 | 16MnDR | 12 | No | 6900 | |||
12 | Cryogenic Liquid | T75 | 19.8,20 | 0.75-2.35 | -196/+50 | Inner Tank: 06Cr19Ni10 | Vacuum With Mutli-wrapped | 8600/12880 | Down load unload | |||
The Main Technical Parameters of Tanks (China Standard) | ||||||||||||
| Loading Medium | Model | Capacity | Design | Design | Tank Material | Nominal Tank | Insulation | Tare weight | Max. Gross Weight | Dimension | Loading Method |
1 | R134a | T50 | 24 | 1.38 | -40 /55 | Q345 (16MnR) | 12 | Sunshade | 6500 | 34000 | 6058 X 2438 X2591 | Down load unload |
2 | R22 | 20 | 2.1 | -40/+50 | 16 | 7850 | ||||||
3 | 24 | 18 | 9100 | |||||||||
4 | R125 | 22 | 2.75 | 22 | 9900 | |||||||
5 | R32 | 22 | 3.44 | 28 | 12000 | |||||||
6 | 23.7 | -40 /55 | 12700 |
Portable tank instruction | PORTABLE TANK INSTRUCTIONSPortable tank instructions also permitted |
T1 | T2, T3, T4, T5, T6, T7, T8, T9, T10, T11, T12, T13, T14, T15, T16, T17, T18, T19, T20, T21, T22 |
T2 | T4, T5, T7, T8, T9, T10, T11, T12, T13, T14, T15, T16, T17, T18, T19, T20, T21, T22 |
T3 | T4, T5, T6, T7, T8, T9, T10, T11, T12, T13, T14, T15, T16, T17, T18, T19, T20, T21, T22 |
T4 | T5, T7, T8, T9, T10, T11, T12, T13, T14, T15, T16, T17, T18, T19, T20, T21, T22 |
T5 | T10, T14, T19, T20, T22 |
T6 | T7, T8, T9, T10, T11, T12, T13, T14, T15, T16, T17, T18, T19, T20, T21, T22 |
T7 | T8, T9, T10, T11, T12, T13, T14, T15, T16, T17, T18, T19, T20, T21, T22 |
T8 | T9, T10, T13, T14, T19, T20, T21, T22 |
T9 | T10, T13, T14, T19, T20, T21, T22 |
T10 | T14, T19, T20, T22 |
T11 | T12, T13, T14, T15, T16, T17, T18, T19, T20, T21, T22 |
T12 | T14, T16, T18, T19, T20, T22 |
T13 | T14, T19, T20, T21, T22 |
T14 | T19, T20, T22 |
T15 | T16, T17, T18, T19, T20, T21, T22 |
T16 | T18, T19, T20, T22 |
T17 | T18, T19, T20, T21, T22 |
T18 | T19, T20, T22 |
T19 | T20, T22 |
T20 | T22 |
T21 | T22 |
T22 | None |
T23 | None |
T Code System for ISO Tank Containers and specifications:
T-Code | Minimum Test Pressure (bar) | Minimum Shell Thickness | Pressure-Relief Requirements | Bottom Opening Requirements |
T1 | 1.5 | > or = 6mm | normal | 2 shut-off devices (Int + Ext) |
T2 | 1.5 | > or = 6mm | normal | 3 shut-off devices (Int + Ext + cap/blank) |
T3 | 2.65 | > or = 6mm | normal | 2 shut-off devices (Int + Ext) |
T4 | 2.65 | > or = 6mm | normal | 3 shut-off devices (Int + Ext + cap/blank) |
T5 | 2.65 | > or = 6mm | normal + rupture disc | Not Allowed |
T6 | 4 | > or = 6mm | normal | 2 shut-off devices (Int + Ext) |
T7 | 4 | > or = 6mm | normal | 3 shut-off devices (Int + Ext + cap/blank) |
T8 | 4 | > or = 6mm | normal | Not Allowed |
T9 | 4 | 6mm | normal | Not Allowed |
T10 | 4 | 6mm | normal + rupture disc | Not Allowed |
T11 | 6 | > or = 6mm | normal | 3 shut-off devices (Int + Ext + cap/blank) |
T12 | 6 | > or = 6mm | normal + rupture disc | 3 shut-off devices (Int + Ext + cap/blank) |
T13 | 6 | 6mm | normal | Not Allowed |
T14 | 6 | 6mm | normal + rupture disc | Not Allowed |
T15 | 10 | >or = 6mm | normal | 3 shut-off devices (Int + Ext + cap/blank) |
T16 | 10 | > or = 6mm | normal + rupture disc | <3 shut-off devices (Int + Ext + cap/blank)/td> |
T17 | 10 | 6mm | normal | 3 shut-off devices (Int + Ext + cap/blank) |
T18 | 10 | 6mm | normal + rupture disc | Not Allowed |
T19 | 10 | 6mm | normal + rupture disc | 3 shut-off devices (Int + Ext + cap/blank) |
T20 | 10 | 8mm | normal + rupture disc | Not Allowed |
T21 | 10 | 10mm | normal | Not Allowed |
T22 | 10 | 10mm | normal + rupture disc | Not Allowed |
T Code System for ISO Tank Containers and specifications:
In addition to the above types of ISO tank container, there are 2 others, namely, a T50 and a T70.
The T50 is a gas tank and has a minimum test pressure of 57.6 bar. Under the IMO system, this was classified IMO5.
The T70 is a cryogenic tank container designed for carrying liquefied gases. Under the IMO system, this was classified IMO7.
T23 PORTABLE TANK INSTRUCTION T23
UN No. | Substance | Minimum test pressure (bar) |
3109 | ORGANIC PEROXIDE, TYPE F, LIQUID tert-Butyl hydro- peroxidea, not more than 72% with water Cumyl hydro-peroxide, not more than 90% in diluent type A Di-tert-butyl peroxide, not more than 32% in diluent type A Isopropyl cumyl hydro- peroxide, not more than 72% in diluent type A p-Menthyl hydro- peroxide, not more than 72% in diluent type A Pinanyl hydro- peroxide, not more than 56% in diluent type A | 4 |
3110 | ORGANIC PEROXIDE TYPE F, SOLID Dicumyl peroxide b | 4 |
3119 | ORGANIC PEROXIDE, TYPE F, LIQUID, TEMPERATURE CONTROLLED | 4 |
tert-Amyl peroxyneodecanoate, not more than 47% in diluent type A | ||
tert-Butyl peroxyacetate, not more than 32% in diluent type B | ||
tert-Butyl peroxy-2- ethylhexanoate, not more than 32% in diluent type B |
a Provided that steps have been taken to achieve the safety equivalence of 65% tert-Butyl hydroperoxide and 35% water.
b Maximum quantity per portable tank: 2000 kg.
UN No. | Substance | Minimum test pressure (bar) | Control tempe- rature | Emergency temperaturef |
3119 (Cont'd) | tert-Butyl peroxypivalate, not more than 27% in diluent type B | +5 °C | +10 °C | |
tert-Butyl peroxy- 3,5,5-trimethyl- hexanoate, not more than 32% in diluent type B | +35 °C | +40 °C | ||
Di-(3,5,5-trimethyl- hexanoyl) peroxide, not more than 38% in diluent type A or type B | 0 °C | +5 °C | ||
Peroxyacetic acid, distilled, type F, stabilized d | +30 °C | +35 °C | ||
3120 | ORGANIC PEROXIDE, TYPE F, SOLID, TEMPERATURE CONTROLLED | 4 | c | c |
3229 | SELF-REACTIVE LIQUID TYPE F | 4 | ||
3230 | SELF-REACTIVE SOLID TYPE F | 4 | ||
3239 | SELF-REACTIVE LIQUID TYPE F, TEMPERATURE CONTROLLED | 4 | c | c |
3240 | SELF-REACTIVE SOLID TYPE F, TEMPERATURE CONTROLLED | 4 | c | c |
UN No. | Non-refrigerated liquefied gases | Max. allowable working pressure (bar): Small; Bare; Sunshield; Insulated; respectivelya | Openings below liquid level | Maximum filling ratio |
1005 | Ammonia, anhydrous | 29.0 25.7 22.0 19.7 | Allowed | 0.53 |
1009 | Bromotrifluoromethane (Refrigerant gas R 13B1) | 38.0 34.0 30.0 27.5 | Allowed | 1.13 |
1010 | Butadienes, stabilized | 7.5 7.0 7.0 7.0 | Allowed | 0.55 |
1010 | Butadienes and hydrocarbon mixture, stabilized | Allowed | ||
1011 | Butane | 7.0 7.0 7.0 7.0 | Allowed | 0.51 |
1012 | Butylene | 8.0 7.0 7.0 7.0 | Allowed | 0.53 |
1017 | Chlorine | 19.0 17.0 15.0 13.5 | Not Allowed | 1.25 |
1018 | Chlorodifluoromethane (Refrigerant gas R 22) | 26.0 24.0 21.0 19.0 | Allowed | 1.03 |
1020 | Chloropentafluoroethane (Refrigerant gas R 115) | 23.0 20.0 18.0 16.0 | Allowed | 1.06 |
1021 | 1-Chloro- 1,2,2,2-tetrafluoroethane (Refrigerant gas R 124) | 10.3 9.8 7.9 7.0 | Allowed | 1.20 |
1027 | Cyclopropane | 18.0 16.0 14.5 13.0 | Allowed | 0.53 |
UN No. | Non-refrigerated liquefied gases | Max. allowable working pressure (bar): Small; Bare; Sunshield; Insulated; respectivelya | Openings below liquid level | Maximum filling ratio |
1028 | Dichlorodifluoromethane (Refrigerant gas R 12) | 16.0 15.0 13.0 11.5 | Allowed | 1.15 |
1029 | Dichlorofluoromethane (Refrigerant gas R 21) | 7.0 7.0 7.0 7.0 | Allowed | 1.23 |
1030 | 1,1-Difluoroethane (Refrigerant gas R 152a) | 16.0 14.0 12.4 11.0 | Allowed | 0.79 |
1032 | Dimethylamine, anhydrous | 7.0 7.0 7.0 7.0 | Allowed | 0.59 |
1033 | Dimethyl ether | 15.5 13.8 12.0 10.6 | Allowed | 0.58 |
1036 | Ethylamine | 7.0 7.0 7.0 7.0 | Allowed | 0.61 |
1037 | Ethyl chloride | 7.0 7.0 7.0 7.0 | Allowed | 0.80 |
1040 | Ethylene oxide with nitrogen up to a total pressure of 1MPa (10 bar) at 50 °C | - - - 10.0 | Not Allowed | 0.78 |
1041 | Ethylene oxide and carbon dioxide mixture with more than 9% but not more than 87% ethylene oxide | Allowed | ||
1055 | Isobutylene | 8.1 7.0 7.0 7.0 | Allowed | 0.52 |
UN No. | Non-refrigerated liquefied gases | Max. allowable working pressure (bar): Small; Bare; Sunshield; Insulated respectivelya | Openings below liquid level | Maximum filling ratio |
1060 | Methylacetylene and propadiene mixture, stabilized | 28.0 24.5 22.0 20.0 | Allowed | 0.43 |
1061 | Methylamine, anhydrous | 10.8 9.6 7.8 7.0 | Allowed | 0.58 |
1062 | Methyl bromide with not more than 2% chloropicrin | 7.0 7.0 7.0 7.0 | Not Allowed | 1.51 |
1063 | Methyl chloride (Refrigerant gas R 40) | 14.5 12.7 11.3 10.0 | Allowed | 0.81 |
1064 | Methyl mercaptan | 7.0 7.0 7.0 7.0 | Not Allowed | 0.78 |
1067 | Dinitrogen tetroxide | 7.0 7.0 7.0 7.0 | Not Allowed | 1.30 |
1075 | Petroleum gases, liquefied | Allowed | ||
1077 | Propylene | 28.0 24.5 22.0 20.0 | Allowed | 0.43 |
1078 | Refrigerant gas, n.o.s. | Allowed | ||
1079 | Sulphur dioxide | 11.6 10.3 8.5 7.6 | Not Allowed | 1.23 |
1082 | Trifluorochloroethylene, stabilized (Refrigerant gas R 1113) | 17.0 15.0 13.1 11.6 | Not Allowed | 1.13 |
UN No. | Non-refrigerated liquefied gases | Max. allowable working pressure (bar): Small; Bare; Sunshield; Insulated respectivelya | Openings below liquid level | Maximum filling ratio |
1083 | Trimethylamine, anhydrous | 7.0 7.0 7.0 7.0 | Allowed | 0.56 |
1085 | Vinyl bromide, stabilized | 7.0 7.0 7.0 7.0 | Allowed | 1.37 |
1086 | Vinyl chloride, stabilized | 10.6 9.3 8.0 7.0 | Allowed | 0.81 |
1087 | Vinyl methyl ether, stabilized | 7.0 7.0 7.0 7.0 | Allowed | 0.67 |
1581 | Chloropicrin and methyl bromide mixture with more than 2% chloropicrin | 7.0 7.0 7.0 7.0 | Not Allowed | 1.51 |
1582 | Chloropicrin and methyl chloride mixture | 19.2 16.9 15.1 13.1 | Not Allowed | 0.81 |
1858 | Hexafluoropropylene (Refrigerant gas R 1216) | 19.2 16.9 15.1 13.1 | Allowed | 1.11 |
1912 | Methyl chloride and methylene chloride mixture | 15.2 13.0 11.6 10.1 | Allowed | 0.81 |
1958 | 1,2-Dichloro-1,1,2,2- tetrafluoroethane (Refrigerant gas R 114) | 7.0 7.0 7.0 7.0 | Allowed | 1.30 |
1965 | Hydrocarbon gas, mixture liquefied, n.o.s. | Allowed | ||
1969 | Isobutane | 8.5 7.5 7.0 7.0 | Allowed | 0.49 |
T50 PORTABLE TANK INSTRUCTION (cont'd) T50 This portable tank instruction applies to non-refrigerated liquefied gases and chemicals under pressure (UN Nos. 3500, 3501, 3502, 3503, 3504 and 3505). The general provisions of Section 4.2.2 and the requirements of Section 6.7.3 shall be met. | |||||
UN No. | Non-refrigerated liquefied gases | Max. allowable working pressure (bar): Small; Bare; Sunshield; Insulated respectivelya | Openings below liquid level | Maximum filling ratio | |
1973 | Chlorodifluoromethane and chloropentafluoroethane mixture with fixed boiling point, with approximately 49% chlorodifluoromethane (Refrigerant gas R 502) | 28.3 25.3 22.8 20.3 | Allowed | Normal | 1.05 |
1974 | Chlorodifluorobromomethane (Refrigerant gas R 12B1) | 7.4 7.0 7.0 7.0 | Allowed | Normal | 1.61 |
1976 | Octafluorocyclobutane (Refrigerant gas RC 318) | 8.8 7.8 7.0 7.0 | Allowed | Normal | 1.34 |
1978 | Propane | 22.5 20.4 18.0 16.5 | Allowed | Normal | 0.42 |
1983 | 1-Chloro-2,2,2-trifluoroethane (Refrigerant gas R 133a) | 7.0 7.0 7.0 7.0 | Allowed | Normal | 1.18 |
2035 | 1,1,1-Trifluoroethane (Refrigerant gas R 143a) | 31.0 27.5 24.2 21.8 | Allowed | Normal | 0.76 |
2424 | Octafluoropropane (Refrigerant gas R 218) | 23.1 20.8 18.6 16.6 | Allowed | Normal | 1.07 |
2517 | 1-Chloro-1,1-difluoroethane (Refrigerant gas R 142b) | 8.9 7.8 7.0 7.0 | Allowed | Normal | 0.99 |
2602 | Dichlorodifluoromethane and 1,1-difluoroethane azeotropic mixture with approximately 74% dichlorodifluoromethane (Refrigerant gas R 500) | 20.0 18.0 16.0 14.5 | Allowed | Normal | 1.01 |
T50 PORTABLE TANK INSTRUCTION (cont'd) T50 This portable tank instruction applies to non-refrigerated liquefied gases and chemicals under pressure (UN Nos. 3500, 3501, 3502, 3503, 3504 and 3505). The general provisions of Section 4.2.2 and the requirements of Section 6.7.3 shall be met. | |||||
UN No. | Non-refrigerated liquefied gases | Max. allowable working pressure (bar): Small; Bare; Sunshield; Insulated; respectivelya | Openings below liquid level | Pressure- relief requirementsb | Maximum filling ratio |
3057 | Trifluoroacetyl chloride | 14.6 12.9 11.3 9.9 | Not allowed | 1.17 | |
3070 | Ethylene oxide and dichlorodifluoromethane mixture with not more than 12.5% ethylene oxide | 14.0 12.0 11.0 9.0 | Allowed | 1.09 | |
3153 | Perfluoro (methyl vinyl ether) | 14.3 13.4 11.2 10.2 | Allowed | Normal | 1.14 |
3159 | 1,1,1,2-Tetrafluoroethane (Refrigerant gas R 134a) | 17.7 15.7 13.8 12.1 | Allowed | Normal | 1.04 |
3161 | Liquefied gas, flammable, n.o.s. | Allowed | Normal | ||
3163 | Liquefied gas, n.o.s. | Allowed | Normal | ||
3220 | Pentafluoroethane (Refrigerant gas R 125) | 34.4 30.8 27.5 24.5 | Allowed | Normal | 0.87 |
3252 | Difluoromethane (Refrigerant gas R 32) | 43.0 39.0 34.4 30.5 | Allowed | Normal | 0.78 |
3296 | Heptafluoropropane (Refrigerant gas R 227) | 16.0 14.0 12.5 11.0 | Allowed | Normal | 1.20 |
3297 | Ethylene oxide and chlorotetrafluoroethane mixture, with not more than 8.8% ethylene oxide | 8.1 7.0 7.0 7.0 | Allowed | Normal | 1.16 |
T50 PORTABLE TANK INSTRUCTION (cont'd) T50 This portable tank instruction applies to non-refrigerated liquefied gases and chemicals under pressure (UN Nos. 3500, 3501, 3502, 3503, 3504 and 3505). The general provisions of Section 4.2.2 and the requirements of Section 6.7.3 shall be met. | |||||
UN No. | Non-refrigerated liquefied gases | Max. allowable working pressure (bar): Small; Bare; Sunshield; Insulated; respectivelya | Openings below liquid level | Maximum filling ratio | |
3298 | Ethylene oxide and pentafluoroethane mixture, with not more than 7.9% ethylene oxide | 25.9 23.4 20.9 18.6 | Allowed | Normal | 1.02 |
3299 | Ethylene oxide and tetrafluoroethane mixture, with not more than 5.6% ethylene oxide | 16.7 14.7 12.9 11.2 | Allowed | Normal | 1.03 |
3318 | Ammonia solution, relative density less than 0.880 at 15 °C in water, with more than 50% ammonia | Allowed | |||
3337 | Refrigerant gas R 404A | 31.6 28.3 25.3 22.5 | Allowed | Normal | 0.84 |
3338 | Refrigerant gas R 407A | 31.3 28.1 25.1 22.4 | Allowed | Normal | 0.95 |
3339 | Refrigerant gas R 407B | 33.0 29.6 26.5 23.6 | Allowed | Normal | 0.95 |
3340 | Refrigerant gas R 407C | 29.9 26.8 23.9 21.3 | Allowed | Normal | 0.95 |
3500 | Chemical under pressure, n.o.s. | Allowed | TP43c | ||
3501 | Chemical under pressure, flammable, n.o.s. | Allowed | TP4c | ||
3502 | Chemical under pressure, toxic, n.o.s. | Allowed | TP4c | ||
3503 | Chemical under pressure, corrosive, n.o.s. | Allowed | TP4c | ||
3504 | Chemical under pressure, flammable, toxic, n.o.s. | Allowed | TP4c | ||
3505 | Chemical under pressure, flammable, corrosive, n.o.s. | Allowed | TP4c |